Humberto, On 31.07.2014 23:01, Humberto Naves wrote: > Hi, > > On Thu, Jul 31, 2014 at 1:45 PM, Sylwester Nawrocki > <s.nawrocki@xxxxxxxxxxx> wrote: >> Can you explain what is rationale behind this change ? Is it related to >> suspend/resume ordering ? > > I had forgotten, but now remember the reason why I did this. If you > see the current implementation of clk-exynos5410, you will notice it > heavily depends on the clock "fin_pll". On the other hand, this clock > exists because in the current dtb (exynos5410-smdk5410.dts), there is > a node fin_pll such as > > fin_pll: xxti { > compatible = "fixed-clock"; > clock-frequency = <24000000>; > clock-output-names = "fin_pll"; > #clock-cells = <0>; > }; > > So far so good. But the real problem comes in when I check the rate of > fin_pll to determine if I should install the rate table or not (and I > really need this for my patch). More specifically > > if (_get_rate("fin_pll") == 24 * MHZ) { > exynos5410_plls[apll].rate_table = apll_24mhz_tbl; > exynos5410_plls[cpll].rate_table = cpll_24mhz_tbl; > exynos5410_plls[kpll].rate_table = kpll_24mhz_tbl; > exynos5410_plls[dpll].rate_table = dpll_24mhz_tbl; > exynos5410_plls[epll].rate_table = epll_24mhz_tbl; > exynos5410_plls[ipll].rate_table = ipll_24mhz_tbl; > } > > I *have* to determine if the rate of fin_pll is 24MHz, and this is > impossible to do if fin_pll is not available. Moreover, there is no > way I can ensure that the fixed clock provider for fin_pll was > initialized before mine, so there is chance that _get_rate won't work. > The only way I fix that is to set the dependency explicitly in the > dtb, by adding the fin_pll clock as required resource. > > clock: clock-controller@10010000 { > compatible = "samsung,exynos5410-clock"; > reg = <0x10010000 0x30000>; > #clock-cells = <1>; > /* Add the parent clock */ > clocks = <&fin_pll>; > clock-names = "fin_pll"; > }; This is the correct solution to your problem. The clocks and clock-names properties should have been there from the beginning but apparently this has been missed in review. Also see below. > > But in any case, the bindings with the DTB must be changed one way or > another, because I *really* need to use fin_pll on my driver > registration. This is a backwards compatible change. On DTBs without clocks and clock-names properties the PLL tables simply won't be registered which is exactly the same behavior we have now without any tables in the driver at all. > If you agree with this alternative solution I previously > described, I can change that in the next version of the patch series. Please update the dts instead, in the way you pointed above. Best regards, Tomasz -- To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html