On 04/09/13 05:25, Heiko Stübner wrote:
Am Montag, 8. April 2013, 21:53:07 schrieb Sylwester Nawrocki:
The external pending interrupt register address (EINTPEND) offset is
0xa8, not 0x08. Without this patch the external interrupts are not
properly acknowledged, which may lead to an interrupt storm and the
system hang as soon as any external interrupt is requested.
Signed-off-by: Sylwester Nawrocki<s.nawrocki@xxxxxxxxxxx>
yep, I unintentionally introduced a typo there and the register really is
0xa8, so thanks (again) for the fix
Reviewed-by: Heiko Stuebner<heiko@xxxxxxxxx>
Applied into fixes for v3.9.
Thanks.
- Kukjin
--
To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html