On 11/2/23 6:34 PM, Wenjia Zhang wrote:
On 02.11.23 06:52, D. Wythe wrote:
From: "D. Wythe" <alibuda@xxxxxxxxxxxxxxxxx>
Considering scenario:
smc_cdc_rx_handler
__smc_release
sock_set_flag
smc_close_active()
sock_set_flag
__set_bit(DEAD) __set_bit(DONE)
Dues to __set_bit is not atomic, the DEAD or DONE might be lost.
if the DEAD flag lost, the state SMC_CLOSED will be never be reached
in smc_close_passive_work:
if (sock_flag(sk, SOCK_DEAD) &&
smc_close_sent_any_close(conn)) {
sk->sk_state = SMC_CLOSED;
} else {
/* just shutdown, but not yet closed locally */
sk->sk_state = SMC_APPFINCLOSEWAIT;
}
Replace sock_set_flags or __set_bit to set_bit will fix this problem.
Since set_bit is atomic.
Signed-off-by: D. Wythe <alibuda@xxxxxxxxxxxxxxxxx>
Reviewed-by: Dust Li <dust.li@xxxxxxxxxxxxxxxxx>
Fixes tag?
ops, i forget that. 🙁
I will fix it in next version.
Thanks.
D. Wythe