On 03.08.22 17:19, Andrew Lunn wrote: > On Wed, Aug 03, 2022 at 04:40:14PM +0200, Alexandra Winter wrote: >> Speed, duplex, port type and link mode can change, after the physical link >> goes down (STOPLAN) or the card goes offline > > If the link is down, speed, and duplex are meaningless. They should be > set to DUPLEX_UNKNOWN, SPEED_UNKNOWN. There is no PORT_UNKNOWN, but > generally, it does not change on link up, so you could set this > depending on the hardware type. > > Andrew Thank you Andrew for the review. I fully understand your point. I would like to propose that I put that on my ToDo list and fix that in a follow-on patch to net-next. The fields in the link_info control blocks are used today to generate other values (e.g. supported speed) which will not work with *_UNKNOWN, so the follow-on patch will be more than just 2 lines. These 2 patches under review are required to solve a recovery problem, so I would like them to go to net asap. Would that be ok for you?