On 23/02/2022 11:02, Fabio M. De Francesco wrote: > smc_pnetid_by_table_ib() uses read_lock() and then it calls smc_pnet_apply_ib() > which, in turn, calls mutex_lock(&smc_ib_devices.mutex). > > read_lock() disables preemption. Therefore, the code acquires a mutex while in > atomic context and it leads to a SAC bug. > > Fix this bug by replacing the rwlock with a mutex. > > Reported-and-tested-by: syzbot+4f322a6d84e991c38775@xxxxxxxxxxxxxxxxxxxxxxxxx > Fixes: 64e28b52c7a6 ("net/smc: add pnet table namespace support") > Confirmed-by: Tony Lu <tonylu@xxxxxxxxxxxxxxxxx> > Signed-off-by: Fabio M. De Francesco <fmdefrancesco@xxxxxxxxx> > --- Thank you Fabio! This should go to the net tree... Acked-by: Karsten Graul <kgraul@xxxxxxxxxxxxx>