Benjamin, > When implementing support for retrieval of local diagnostic data from > the FCP channel, the wrong data format was assumed for the temperature > of the local SFP+ connector. The Fibre Channel Link Services (FC-LS-3) > specification is not clear on the format of the stored integer, and > only after consulting the SNIA specification SFF-8472 did we realize > it is stored as two's complement. Thus, the used data and display > format is wrong, and highly misleading for users when the temperature > should drop below 0°C (however unlikely that may be). Applied to 5.6/scsi-fixes, thanks! -- Martin K. Petersen Oracle Linux Engineering