On Fri, 22 Nov 2024 11:10:30 +0100, Maxime Chevallier wrote: > The undervoltage flags reported by the RTC are useful to know if the > time and date are reliable after a reboot. Although the threshold VLOW1 > indicates that the thermometer has been shutdown and time compensation > is off, it doesn't mean that the temperature readout is currently > impossible. > > As the system is running, the RTC voltage is now fully established and > we can read the temperature. > > [...] Applied, thanks! [2/2] rtc: ab-eoz9: don't fail temperature reads on undervoltage notification https://git.kernel.org/abelloni/c/e0779a0dcf41 Best regards, -- Alexandre Belloni, co-owner and COO, Bootlin Embedded Linux and Kernel engineering https://bootlin.com