On 17.06.2024 10:16, claudiu beznea wrote: > > > On 16.06.2024 10:38, Krzysztof Kozlowski wrote: >> On 14/06/2024 09:19, Claudiu wrote: >>> From: Claudiu Beznea <claudiu.beznea.uj@xxxxxxxxxxxxxx> >> >>> + >>> +maintainers: >>> + - Claudiu Beznea <claudiu.beznea.uj@xxxxxxxxxxxxxx> >>> + >>> +properties: >>> + compatible: >>> + items: >>> + - const: renesas,rzg3s-vbattb >>> + - const: syscon >>> + - const: simple-mfd >> >> No, mfd does no look good. That's not a simple device anymore and you >> claim here child does not need vbat bclk, power domains and resets? That >> would be a big surprise, although technically possible. > > I wasn't sure how this MFD will be received by the Renesas maintainers so I > kept it simple for this version. > > In theory the VBAT clk, power domain and resets are specific to VBAT module > itself but, indeed, the child cannot work w/o these. > >> >> Please clarify: which of parent resources are needed for children? > > VBAT clock, power domain are needed. Reset, too. In the current > implementation the reset is deasserted though parent by calling the > syscon_node_to_regmap(np->parent) in the clock driver. > >> >> ... >> >>> + >>> +additionalProperties: false >>> + >>> +examples: >>> + - | >>> + #include <dt-bindings/clock/r9a08g045-cpg.h> >>> + #include <dt-bindings/interrupt-controller/arm-gic.h> >>> + >>> + vbattb: vbattb@1005c000 { >>> + compatible = "renesas,rzg3s-vbattb", "syscon", "simple-mfd"; >>> + reg = <0x1005c000 0x1000>; >>> + ranges = <0 0 0x1005c000 0 0x1000>; >>> + interrupts = <GIC_SPI 43 IRQ_TYPE_LEVEL_HIGH>; >>> + interrupt-names = "tampdi"; >>> + clocks = <&cpg CPG_MOD R9A08G045_VBAT_BCLK>; >>> + clock-names = "bclk"; >>> + power-domains = <&cpg>; >>> + resets = <&cpg R9A08G045_VBAT_BRESETN>; >>> + #address-cells = <2>; >>> + #size-cells = <2>; >>> + status = "disabled"; >> >> Drop > > Could you please clarify this? Would you want me to drop the full node > (same for clock-controller node)? Looking at your review on patch 05/12 from this series I noticed you're taking about the status = "disabled" lines. I'll drop it as suggested. Thank you, Claudiu Beznea > > Can you point me an example that you are thinking about? > > Thank you, > Claudiu Beznea > >> >>> + >>> + vbattclk: clock-controller@1c { >>> + compatible = "renesas,rzg3s-vbattb-clk"; >>> + reg = <0 0x1c 0 0x10>; >>> + clocks = <&cpg CPG_MOD R9A08G045_VBAT_BCLK>, <&vbattb_xtal>; >>> + clock-names = "bclk", "vbattb_xtal"; >>> + #clock-cells = <0>; >>> + power-domains = <&cpg>; >>> + status = "disabled"; >> >> Drop >> >>> + }; >>> + }; >>> + >>> +... >> >> Best regards, >> Krzysztof >>