HDC2010 and HDC2080 humidity sensors both have an interrupt / data-ready signal which can be used for signaling to the host. Add binding for "interrupts" property so that boards wiring this signal may describe the connection. Signed-off-by: Josua Mayer <josua@xxxxxxxxxxxxx> --- Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml | 3 +++ 1 file changed, 3 insertions(+) diff --git a/Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml b/Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml index 79e75a8675cb..e3eca8917517 100644 --- a/Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml +++ b/Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml @@ -27,6 +27,9 @@ properties: reg: maxItems: 1 + interrupts: + maxItems: 1 + required: - compatible - reg -- 2.35.3