On Wed, Mar 22, 2023 at 10:10:23AM +0100, Julien Panis wrote: > Question @ Mark/Liam: > Shouldn't we use the generic 'regulator-coupled-with' property > instead of 'ti,multi-phase-id' ? My understanding was that this was a hardware configuration where two regulators operate as one with only one set of registers used for configuration. > I am in charge of upstreaming dt-bindings and maintainers > pointed out the similarity between 'multi-phase' and 'coupled' > regulator concepts. Does 'regulator-coupled-with' mean that > outputs of buck converters are combined ? If so, this generic > property should replace our specific 'ti,multi-phase-id' prop, > I guess. No, coupled regulators are regulators where the voltages can vary but there's a constraint that their configurations need to be related somehow, for example they must be within 200mV of each other or something like that.