On Mon, 29 Aug 2022 14:46:39 +0200, paulmn wrote: > Bugfix for an issue detected when a goldcap capacitor gets > fully discharged due to a long absence of the power supply, > and then recharges again. The RTC failed to continue to keep > the real-time clock. > > This was caused by the incorrect handling of the STOP bit in > the RTC internal register. This fix solves the problem. > > [...] Applied, thanks! [1/1] rtc: pcf8523: fix for stop bit commit: fe0157ba679dc95407dd5eae6550a4ceaea75040 Best regards, -- Alexandre Belloni, co-owner and COO, Bootlin Embedded Linux and Kernel engineering https://bootlin.com