Hi Andre! Dne petek, 23. julij 2021 ob 17:38:34 CEST je Andre Przywara napisal(a): > The H616 RTC changes its day storage to the newly introduced linear day > scheme, so pair the new compatible string with this feature flag. > The clock part is missing an external 32768 Hz oscillator input pin, > for future expansion we must thus ignore any provided clock for now. > > Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx> > --- > drivers/rtc/rtc-sun6i.c | 19 +++++++++++++++++++ > 1 file changed, 19 insertions(+) > Reviewed-by: Jernej Skrabec <jernej.skrabec@xxxxxxxxx> Best regards, Jernej