Re: [PATCH 3/3] rtc: rx8010: Fix for incorrect return value

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 03/11/2017 at 13:32:41 -0400, Akshay Bhat wrote:
> The err variable is not being reset after a successful read. Explicitly
> reset err variable to account for all return paths.
> 
> Reported-by: Jens-Peter Oswald <oswald@xxxxxx>
> Signed-off-by: Akshay Bhat <akshay.bhat@xxxxxxxxxxx>
> ---
>  drivers/rtc/rtc-rx8010.c | 2 ++
>  1 file changed, 2 insertions(+)
> 
> diff --git a/drivers/rtc/rtc-rx8010.c b/drivers/rtc/rtc-rx8010.c
> index 2e06e5f..1ce2078 100644
> --- a/drivers/rtc/rtc-rx8010.c
> +++ b/drivers/rtc/rtc-rx8010.c
> @@ -223,6 +223,7 @@ static int rx8010_init_client(struct i2c_client *client)
>  					    2, ctrl);
>  	if (err != 2)
>  		return err < 0 ? err : -EIO;
> +	err = 0;

Isn't it simpler to make the function return 0 instead of err at the end?

>  
>  	if (ctrl[0] & RX8010_FLAG_VLF)
>  		dev_warn(&client->dev, "Frequency stop was detected\n");
> @@ -261,6 +262,7 @@ static int rx8010_read_alarm(struct device *dev, struct rtc_wkalrm *t)
>  	err = i2c_smbus_read_i2c_block_data(client, RX8010_ALMIN, 3, alarmvals);
>  	if (err != 3)
>  		return err < 0 ? err : -EIO;
> +	err = 0;

ditto

>  
>  	flagreg = i2c_smbus_read_byte_data(client, RX8010_FLAG);
>  	if (flagreg < 0)
> -- 
> 2.7.4
> 

-- 
Alexandre Belloni, Free Electrons