Re: [PATCH 3/3] arm64: dts: rk3399: Add init voltage for vdd_log

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Markus,


On 2019/11/12 下午4:16, Markus Reichl wrote:
Hi Kever,

have a rk3399-roc-pc running mainline U-Boot and kernel and vdd_log is
showing 1118 mV.

The rk3399-roc-pc have the same vdd_log circuit in schematic, so it should like the patch 1/3 of

this patch set.

I don't understand who is setting this value, maybe the default value without pwm regulator enabled?

Is this a danger for the board?
How to fix it?

The best way is to set correct min/max microvolt of the regulator(measure with PWM output low and high),

(note that if  no driver touch the regulator, the PWM is default input, not output;)

and set a init-microvolt for U-Boot driver, and I think no kernel driver touch this regulator now.


Thanks,

- Kever

Btw. vin-supply for this pwm-regulator is ignored and I could not find it
in bindings doc.

Gruß,



_______________________________________________
Linux-rockchip mailing list
Linux-rockchip@xxxxxxxxxxxxxxxxxxx
http://lists.infradead.org/mailman/listinfo/linux-rockchip