Am Montag, 5. M?rz 2018, 09:57:39 CET schrieb Marek Szyprowski: > From: zain wang <wzz at rock-chips.com> > > The bridge does not need to be powered in analogix_dp_bind(), so > remove the calls to pm_runtime_get()/phy_power_on()/analogix_dp_init_dp() > as well as their power-off counterparts. > > Cc: St?phane Marchesin <marcheu at chromium.org> > Signed-off-by: zain wang <wzz at rock-chips.com> > Signed-off-by: Caesar Wang <wxt at rock-chips.com> > [the patch originally just removed the power_on portion, seanpaul removed > the power off code as well as improved the commit message] > Signed-off-by: Sean Paul <seanpaul at chromium.org> > Signed-off-by: Thierry Escande <thierry.escande at collabora.com> > Signed-off-by: Marek Szyprowski <m.szyprowski at samsung.com> on top of current drm-misc-next on rk3288 and rk3399 Tested-by: Heiko Stuebner <heiko at sntech.de> and the actual change also looks sane of course, so Reviewed-by: Heiko Stuebner <heiko at sntech.de>