On 05/04/2015 at 02:20:24 +0200, Heiko St?bner wrote : > The hym8563 datasheet describes the clock output control-bit as "when set > to logic 0, the square wave output is enable, when set to logic 1, the > CLKOUT output is inhibited". But in reality the setting is exactly > opposite. > > Before now, the clock output was not really used, but on the rk3288 soc > this generated clock is used to supply the temperature sensor block and > the swapped bit value prevented it from working. With the corrected value, > the tsadc now reports correct values. > > Signed-off-by: Heiko Stuebner <heiko at sntech.de> Acked-by: Alexandre Belloni <alexandre.belloni at free-electrons.com> Should that patch be applied on any stable version too? -- Alexandre Belloni, Free Electrons Embedded Linux, Kernel and Android engineering http://free-electrons.com