Re: [PATCH 0/2] Update correct procedure for clearing alarm

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Tue, 18 Jun 2024 16:26:29 +0100, Biju Das wrote:
> As per the latest HW manual[1], the INT# output is pulled low after the
> alarm is triggered. After the INT# output is pulled low, it is low for at
> least 250ms, even if the correct action is taken to clear it. It is
> impossible to clear ALM if it is still active. The host must wait for the
> RTC to progress past the alarm time plus the 250ms delay before clearing
> ALM. Apart from this, there is an internal delay(~250 microsec) from
> setting ALME = 0 to disabling the alarm function, so the user must add a
> short delay of greater than 250µs between setting ALME = 0 and clearing
> ALM.
> 
> [...]

Applied, thanks!

[1/2] rtc: isl1208: Add a delay for clearing alarm
      https://git.kernel.org/abelloni/c/0dbd610c426e
[2/2] rtc: isl1208: Update correct procedure for clearing alarm
      https://git.kernel.org/abelloni/c/43696b3a9e46

Best regards,

-- 
Alexandre Belloni, co-owner and COO, Bootlin
Embedded Linux and Kernel engineering
https://bootlin.com




[Index of Archives]     [Linux Samsung SOC]     [Linux Wireless]     [Linux Kernel]     [ATH6KL]     [Linux Bluetooth]     [Linux Netdev]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Samba]     [Device Mapper]

  Powered by Linux