On Fri, Feb 9, 2024 at 12:56 AM Kuninori Morimoto <kuninori.morimoto.gx@xxxxxxxxxxx> wrote: > From: Dien Pham <dien.pham.ry@xxxxxxxxxxx> > > Description in HWM rev0.51E, 9.4 Usage notes, page 455 tells > > "It takes several hundreds of microseconds to shutting off and > resuming power domain. Because actual time required for > shutting off and resuming depends on the status of on-board > power line, shutoff/resume time is not guaranteed by > electrical specification" > > Let's assume the safe value of waiting is about 1000us. > > Signed-off-by: Dien Pham <dien.pham.ry@xxxxxxxxxxx> > Signed-off-by: Takeshi Kihara <takeshi.kihara.df@xxxxxxxxxxx> > Signed-off-by: Tho Vu <tho.vu.wh@xxxxxxxxxxx> > Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> I think you can drop that line ;-) > Signed-off-by: Kuninori Morimoto <kuninori.morimoto.gx@xxxxxxxxxxx> Reviewed-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> Gr{oetje,eeting}s, Geert -- Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- geert@xxxxxxxxxxxxxx In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that. -- Linus Torvalds