According to Table 8.1, "Summary of Module Power, Reset condition and Clock assignment" of the R-Mobile APE6 Hardware Manual Rev. 0.7, the parent clock of the thermal sensor clock is the Common Peripheral (CP) clock, which runs at 13 MHz (main clock / 2). As the R-Car Thermal driver does not use the clock rate, this change has no functional impact. Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> --- arch/arm/boot/dts/renesas/r8a73a4.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/arch/arm/boot/dts/renesas/r8a73a4.dtsi b/arch/arm/boot/dts/renesas/r8a73a4.dtsi index 6847acaecc809eaa..b3d5c154cfc1b8c1 100644 --- a/arch/arm/boot/dts/renesas/r8a73a4.dtsi +++ b/arch/arm/boot/dts/renesas/r8a73a4.dtsi @@ -814,7 +814,7 @@ R8A73A4_CLK_IIC3 mstp5_clks: mstp5_clks@e6150144 { compatible = "renesas,r8a73a4-mstp-clocks", "renesas,cpg-mstp-clocks"; reg = <0 0xe6150144 0 4>, <0 0xe615003c 0 4>; - clocks = <&extal2_clk>, <&cpg_clocks R8A73A4_CLK_HP>; + clocks = <&cp_clk>, <&cpg_clocks R8A73A4_CLK_HP>; #clock-cells = <1>; clock-indices = < R8A73A4_CLK_THERMAL R8A73A4_CLK_IIC8 -- 2.34.1