Commit 45c940184b501fc6 ("dt-bindings: clk: versaclock5: convert to yaml") accidentally changed "idt,voltage-microvolts" to "idt,voltage-microvolt" in the DT bindings, while the driver still used the former. Update the driver to match the bindings, as Documentation/devicetree/bindings/property-units.txt actually recommends using "microvolt". Fixes: 260249f929e81d3d ("clk: vc5: Enable addition output configurations of the Versaclock") Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> --- There are no upstream users yet, but they are planned for v5.12, so I think this should be in v5.11-rc1. Thanks! --- drivers/clk/clk-versaclock5.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/clk/clk-versaclock5.c b/drivers/clk/clk-versaclock5.c index c90460e7ef2153fe..43db67337bc06824 100644 --- a/drivers/clk/clk-versaclock5.c +++ b/drivers/clk/clk-versaclock5.c @@ -739,8 +739,8 @@ static int vc5_update_power(struct device_node *np_output, { u32 value; - if (!of_property_read_u32(np_output, - "idt,voltage-microvolts", &value)) { + if (!of_property_read_u32(np_output, "idt,voltage-microvolt", + &value)) { clk_out->clk_output_cfg0_mask |= VC5_CLK_OUTPUT_CFG0_PWR_MASK; switch (value) { case 1800000: -- 2.25.1