If a hardware-specific driver does not provide a name, the timer-of core falls back to device_node.name. Due to generic DT node naming policies, that name is almost always "timer", and thus doesn't identify the actual timer used. Fix this by using device_node.full_name instead, which includes the unit addrees. Example impact on /proc/timer_list: -Clock Event Device: timer +Clock Event Device: timer@fcfec400 Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> --- v4: - New. --- drivers/clocksource/timer-of.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/clocksource/timer-of.c b/drivers/clocksource/timer-of.c index 92cfb160657b81e2..572da477c6d35c5e 100644 --- a/drivers/clocksource/timer-of.c +++ b/drivers/clocksource/timer-of.c @@ -192,7 +192,7 @@ int __init timer_of_init(struct device_node *np, struct timer_of *to) } if (!to->clkevt.name) - to->clkevt.name = np->name; + to->clkevt.name = np->full_name; to->np = np; -- 2.17.1