On Fri, Aug 16, 2019 at 02:52:23PM +0200, Geert Uytterhoeven wrote: > The CPG/MSTP Clock Domain driver does not implement the > generic_pm_domain.power_{on,off}() callbacks, as the domain itself > cannot be powered down. Hence the domain should be marked as always-on > by setting the GENPD_FLAG_ALWAYS_ON flag. > > This gets rid of the following boot warning on RZ/A1: > > sh_mtu2 fcff0000.timer: PM domain cpg_clocks will not be powered off > > Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> Reviewed-by: Simon Horman <horms+renesas@xxxxxxxxxxxx>