On r8a7791/koelsch: m25p80 spi0.0: error -22 reading 9f m25p80: probe of spi0.0 failed with error -22 Apparently the logic in spi_mem_check_op() is wrong, rejecting the spi-mem operation if any buswidth is valid, instead of invalid. Fixes: 380583227c0c7f52 ("spi: spi-mem: Add extra sanity checks on the op param") Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> --- drivers/spi/spi-mem.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/drivers/spi/spi-mem.c b/drivers/spi/spi-mem.c index cc3d425aae56c634..62a7b80801d22098 100644 --- a/drivers/spi/spi-mem.c +++ b/drivers/spi/spi-mem.c @@ -169,10 +169,10 @@ static int spi_mem_check_op(const struct spi_mem_op *op) (op->data.nbytes && !op->data.buswidth)) return -EINVAL; - if (spi_mem_buswidth_is_valid(op->cmd.buswidth) || - spi_mem_buswidth_is_valid(op->addr.buswidth) || - spi_mem_buswidth_is_valid(op->dummy.buswidth) || - spi_mem_buswidth_is_valid(op->data.buswidth)) + if (!spi_mem_buswidth_is_valid(op->cmd.buswidth) || + !spi_mem_buswidth_is_valid(op->addr.buswidth) || + !spi_mem_buswidth_is_valid(op->dummy.buswidth) || + !spi_mem_buswidth_is_valid(op->data.buswidth)) return -EINVAL; return 0; -- 2.17.1