Hi Geert, On Friday, 8 June 2018 14:53:28 EEST Geert Uytterhoeven wrote: > On Fri, Jun 8, 2018 at 1:18 PM Laurent Pinchart wrote: > > The R8A77995 VSP and FCP nodes have overlapping register ranges, as the > > SoC integrates the FCP devices in the memory range usually used by the > > VSP LUT and CLUT, which are not present. Fix this by shortening the VSP > > registers range to 0x5000. > > According to datasheet rev. 1.00, the CLUT is present on R-Car D3, the > LUT is not. That was a typo, the commit message should have mentioned CLU, not CLUT. I've sent a v2 that fixes this and covers the H3 and M3* SoCs. > > Fixes: 295952a183d3 ("arm64: dts: renesas: r8a77995: add VSP instances") > > Reported-by: Simon Horman <horms+renesas@xxxxxxxxxxxx> > > Reported-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> > > Signed-off-by: Laurent Pinchart > > <laurent.pinchart+renesas@xxxxxxxxxxxxxxxx> > > Apart from my comment above: > Reviewed-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> -- Regards, Laurent Pinchart