Document r8a774[35] specific compatible strings. No driver change is needed as the fallback compatible string "renesas,tpu" activates the right code in the driver. Signed-off-by: Fabrizio Castro <fabrizio.castro@xxxxxxxxxxxxxx> Reviewed-by: Biju Das <biju.das@xxxxxxxxxxxxxx> Reviewed-by: Rob Herring <robh@xxxxxxxxxx> Reviewed-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> --- v1->v2 * No change Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt b/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt index 1aadc80..16e5748 100644 --- a/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt +++ b/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt @@ -5,8 +5,10 @@ Required Properties: - compatible: should be one of the following. - "renesas,tpu-r8a73a4": for R8A77A4 (R-Mobile APE6) compatible PWM controller. - "renesas,tpu-r8a7740": for R8A7740 (R-Mobile A1) compatible PWM controller. + - "renesas,tpu-r8a7743": for R8A7743 (RZ/G1M) compatible PWM controller. + - "renesas,tpu-r8a7745": for R8A7745 (RZ/G1E) compatible PWM controller. - "renesas,tpu-r8a7790": for R8A7790 (R-Car H2) compatible PWM controller. - - "renesas,tpu": for generic R-Car TPU PWM controller. + - "renesas,tpu": for generic R-Car and RZ/G1 TPU PWM controller. - reg: Base address and length of each memory resource used by the PWM controller hardware module. -- 2.7.4