Hi Jacopo, On Fri, Mar 24, 2017 at 4:28 PM, Jacopo Mondi <jacopo+renesas@xxxxxxxxxx> wrote: > output reported from iio_info tool: > iio:device0: max9611_vdd > 6 channels found: > temp: (input) > 2 channel-specific attributes found: > attr 0: scale value: 0.480076812 > attr 1: raw value: 59 According to Documentation/ABI/testing/sysfs-bus-iio, temperature units after application of scale and offset are milli degrees Celsius, so your scale value should be 480.076812. BTW, mine runs 3 degrees cooler, but it's located in the coldest room in my house ;-) Gr{oetje,eeting}s, Geert -- Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- geert@xxxxxxxxxxxxxx In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that. -- Linus Torvalds