The power domain must be specified to bring the device out of module standby. Document this in the example provided, so that new additions are not missed. Signed-off-by: Kieran Bingham <kieran@xxxxxxxxxxx> --- Documentation/devicetree/bindings/media/renesas,fcp.txt | 1 + 1 file changed, 1 insertion(+) diff --git a/Documentation/devicetree/bindings/media/renesas,fcp.txt b/Documentation/devicetree/bindings/media/renesas,fcp.txt index 271dcfdb5a76..6a55f5215221 100644 --- a/Documentation/devicetree/bindings/media/renesas,fcp.txt +++ b/Documentation/devicetree/bindings/media/renesas,fcp.txt @@ -31,4 +31,5 @@ Device node example compatible = "renesas,r8a7795-fcpv", "renesas,fcpv"; reg = <0 0xfea2f000 0 0x200>; clocks = <&cpg CPG_MOD 602>; + power-domains = <&sysc R8A7795_PD_A3VP>; }; -- 2.7.4