From: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> Hook up the RWDT device node to the SYSC "always-on" PM Domain, for a more consistent device-power-area description in DT. Cfr. commit 38dbb45ee4bc ("arm64: dts: r8a7795: Use SYSC "always-on" PM Domain") Fixes: f43838a7ae014cba ("arm64: dts: r8a7795: Add RWDT node") Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> Signed-off-by: Simon Horman <horms+renesas@xxxxxxxxxxxx> --- arch/arm64/boot/dts/renesas/r8a7795.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/arch/arm64/boot/dts/renesas/r8a7795.dtsi b/arch/arm64/boot/dts/renesas/r8a7795.dtsi index ba87e03969ee..bf38df355006 100644 --- a/arch/arm64/boot/dts/renesas/r8a7795.dtsi +++ b/arch/arm64/boot/dts/renesas/r8a7795.dtsi @@ -168,7 +168,7 @@ compatible = "renesas,r8a7795-wdt", "renesas,rcar-gen3-wdt"; reg = <0 0xe6020000 0 0x0c>; clocks = <&cpg CPG_MOD 402>; - power-domains = <&cpg>; + power-domains = <&sysc R8A7795_PD_ALWAYS_ON>; status = "disabled"; }; -- 2.1.4