On 6/28/24 14:58, Mathieu Poirier wrote:
This could lead in an incorrect IPC-only mode detection if reset line is
asserted (so reset_control_status() return > 0) and c_state != 0 and
halted == 0.
In this case, the old code would have detected an IPC-only mode instead
of a mismatched mode.
Your assessment seems to be correct. That said I'd like to have an RB or a TB
from someone in the TI delegation - guys please have a look.
Agree with Richard's assessment, and the proposed fix looks good.
Reviewed-by:
Hari Nagalla <hnagalla@xxxxxx>