Re: RDMA subsystem namespace related questions (was Re: Finding the namespace of a struct ib_device)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Sep 30, 2020 at 06:32:28PM +0800, Ka-Cheong Poon wrote:
> After the aforementioned check on a namespace, what can the client
> do?  It still needs to use the existing ib_register_client() to
> register with RDMA subsystem.  And after registration, it will get
> notifications for all add/remove upcalls on devices not related
> to the namespace it is interested in.  The client can work around
> this if there is a supported way to find out the namespace of a
> device, hence the original proposal of having rdma_dev_to_netns().

Yes, the client would have to check the netns and abort client
registration.

Arguably many of our current clients are wrong in this area since they
only work on init_net anyhow.

It would make sense to introduce a rdma_dev_to_netns() and use it to
block clients on ULPs that use the CM outside init_net.

> that namespace to use it.  If there are a large number of namespaces,
> there won't be enough devices to assign to all of them (e.g. the
> hardware I have access to only supports up to 24 VFs).  The shared
> mode can be used in this case.  Could you please explain what needs
> to be done to support a large number of namespaces in exclusive
> mode?

Modern HW supports many more than 24 VFs, this is the expected
interface

> BTW, if exclusive mode is the future, it may make sense to have
> something like rdma_[un]register_net_client().

I don't think we need this

> > > A new connection comes in and the event handler is called for an
> > > RDMA_CM_EVENT_CONNECT_REQUEST event.  There is no obvious namespace info regarding
> > > the event.  It seems that the only way to find out the namespace info is to
> > > use the context of struct rdma_cm_id.
> > 
> > The rdma_cm_id has only a single namespace, the ULP knows what it is
> > because it created it. A listening ID can't spawn new IDs in different
> > namespaces.
> 
> The problem is that the handler is not given the listener's
> rdma_cm_id when it is called.  It is only given the new rdma_cm_id.

The new cm_id starts with the same ->context as the listener, the ULP should
use this to pass any data, such as the namespace.

> > It seems like a ULP error to drive cm_id lifetime entirely from the
> > per-net stuff.
>
> It is not an ULP error.  While there are many reasons to delete
> a listener, it is not necessary for the listener to die unless the
> namespace is going away.

It certainly currently is.

I'm skeptical ULPs should be doing per-ns stuff like that. A ns aware
ULP should fundamentally be linked to some FD and the ns to use should
derived from the process that FD is linked to. Keeping per-ns stuff
seems wrong.

Jason