It will print the warning when the msb bit of slid is not zero running cm_req_handler function that test CM. It needs to fixed zero when test RoCE device. Signed-off-by: Lijun Ou <oulijun@xxxxxxxxxx> --- drivers/infiniband/hw/hns/hns_roce_hw_v2.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/infiniband/hw/hns/hns_roce_hw_v2.c b/drivers/infiniband/hw/hns/hns_roce_hw_v2.c index e18b8f2..06fc1df 100644 --- a/drivers/infiniband/hw/hns/hns_roce_hw_v2.c +++ b/drivers/infiniband/hw/hns/hns_roce_hw_v2.c @@ -2328,6 +2328,7 @@ static int hns_roce_v2_poll_one(struct hns_roce_cq *hr_cq, wc->src_qp = (u8)roce_get_field(cqe->byte_32, V2_CQE_BYTE_32_RMT_QPN_M, V2_CQE_BYTE_32_RMT_QPN_S); + wc->slid = 0; wc->wc_flags |= (roce_get_bit(cqe->byte_32, V2_CQE_BYTE_32_GRH_S) ? IB_WC_GRH : 0); -- 1.9.1