[PATCH rdma-next 11/27] RDMA/mlx5: Add NIC TX steering support

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



From: Mark Bloch <markb@xxxxxxxxxxxx>

Add support for proper NIC TX (egress) steering with multiple priorities.
We expose the same number of priorities as the bypass (NIC RX) steering.

Signed-off-by: Mark Bloch <markb@xxxxxxxxxxxx>
Signed-off-by: Leon Romanovsky <leonro@xxxxxxxxxxxx>
---
 drivers/infiniband/hw/mlx5/main.c    | 28 ++++++++++++++++++----------
 drivers/infiniband/hw/mlx5/mlx5_ib.h |  1 +
 2 files changed, 19 insertions(+), 10 deletions(-)

diff --git a/drivers/infiniband/hw/mlx5/main.c b/drivers/infiniband/hw/mlx5/main.c
index 9011187ca081..b3281e408d2a 100644
--- a/drivers/infiniband/hw/mlx5/main.c
+++ b/drivers/infiniband/hw/mlx5/main.c
@@ -2883,7 +2883,7 @@ is_valid_esp_aes_gcm(struct mlx5_core_dev *mdev,
 	 * rules would be supported, always return VALID_SPEC_NA.
 	 */
 	if (!is_crypto)
-		return egress ? VALID_SPEC_INVALID : VALID_SPEC_NA;
+		return VALID_SPEC_NA;
 
 	return is_crypto && is_ipsec &&
 		(!egress || (!is_drop && !flow_act->has_flow_tag)) ?
@@ -3058,21 +3058,26 @@ static struct mlx5_ib_flow_prio *get_flow_table(struct mlx5_ib_dev *dev,
 	max_table_size = BIT(MLX5_CAP_FLOWTABLE_NIC_RX(dev->mdev,
 						       log_max_ft_size));
 	if (flow_attr->type == IB_FLOW_ATTR_NORMAL) {
-		if (ft_type == MLX5_IB_FT_TX)
-			priority = 0;
-		else if (flow_is_multicast_only(flow_attr) &&
-			 !dont_trap)
+		enum mlx5_flow_namespace_type fn_type;
+
+		if (flow_is_multicast_only(flow_attr) &&
+		    !dont_trap)
 			priority = MLX5_IB_FLOW_MCAST_PRIO;
 		else
 			priority = ib_prio_to_core_prio(flow_attr->priority,
 							dont_trap);
-		ns = mlx5_get_flow_namespace(dev->mdev,
-					     ft_type == MLX5_IB_FT_TX ?
-					     MLX5_FLOW_NAMESPACE_EGRESS :
-					     MLX5_FLOW_NAMESPACE_BYPASS);
+		if (ft_type == MLX5_IB_FT_RX) {
+			fn_type = MLX5_FLOW_NAMESPACE_BYPASS;
+			prio = &dev->flow_db->prios[priority];
+		} else {
+			max_table_size = BIT(MLX5_CAP_FLOWTABLE_NIC_TX(dev->mdev,
+								       log_max_ft_size));
+			fn_type = MLX5_FLOW_NAMESPACE_EGRESS;
+			prio = &dev->flow_db->egress_prios[priority];
+		}
+		ns = mlx5_get_flow_namespace(dev->mdev, fn_type);
 		num_entries = MLX5_FS_MAX_ENTRIES;
 		num_groups = MLX5_FS_MAX_TYPES;
-		prio = &dev->flow_db->prios[priority];
 	} else if (flow_attr->type == IB_FLOW_ATTR_ALL_DEFAULT ||
 		   flow_attr->type == IB_FLOW_ATTR_MC_DEFAULT) {
 		ns = mlx5_get_flow_namespace(dev->mdev,
@@ -3271,6 +3276,9 @@ static struct mlx5_ib_flow_handler *_create_flow_rule(struct mlx5_ib_dev *dev,
 	if (!is_valid_attr(dev->mdev, flow_attr))
 		return ERR_PTR(-EINVAL);
 
+	if (dev->rep && is_egress)
+		return ERR_PTR(-EINVAL);
+
 	spec = kvzalloc(sizeof(*spec), GFP_KERNEL);
 	handler = kzalloc(sizeof(*handler), GFP_KERNEL);
 	if (!handler || !spec) {
diff --git a/drivers/infiniband/hw/mlx5/mlx5_ib.h b/drivers/infiniband/hw/mlx5/mlx5_ib.h
index 462505c8fa25..01bef4c2d396 100644
--- a/drivers/infiniband/hw/mlx5/mlx5_ib.h
+++ b/drivers/infiniband/hw/mlx5/mlx5_ib.h
@@ -188,6 +188,7 @@ struct mlx5_ib_flow_matcher {
 
 struct mlx5_ib_flow_db {
 	struct mlx5_ib_flow_prio	prios[MLX5_IB_NUM_FLOW_FT];
+	struct mlx5_ib_flow_prio	egress_prios[MLX5_IB_NUM_FLOW_FT];
 	struct mlx5_ib_flow_prio	sniffer[MLX5_IB_NUM_SNIFFER_FTS];
 	struct mlx5_ib_flow_prio	egress[MLX5_IB_NUM_EGRESS_FTS];
 	struct mlx5_flow_table		*lag_demux_ft;
-- 
2.14.4

--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Photo]     [Yosemite News]     [Yosemite Photos]     [Linux Kernel]     [Linux SCSI]     [XFree86]

  Powered by Linux