On 02.11.23 06:52, D. Wythe wrote:
From: "D. Wythe" <alibuda@xxxxxxxxxxxxxxxxx> Considering scenario: smc_cdc_rx_handler __smc_release sock_set_flag smc_close_active() sock_set_flag __set_bit(DEAD) __set_bit(DONE) Dues to __set_bit is not atomic, the DEAD or DONE might be lost. if the DEAD flag lost, the state SMC_CLOSED will be never be reached in smc_close_passive_work: if (sock_flag(sk, SOCK_DEAD) && smc_close_sent_any_close(conn)) { sk->sk_state = SMC_CLOSED; } else { /* just shutdown, but not yet closed locally */ sk->sk_state = SMC_APPFINCLOSEWAIT; } Replace sock_set_flags or __set_bit to set_bit will fix this problem. Since set_bit is atomic. Signed-off-by: D. Wythe <alibuda@xxxxxxxxxxxxxxxxx> Reviewed-by: Dust Li <dust.li@xxxxxxxxxxxxxxxxx>
Fixes tag?