On Mon, 2022-02-21 at 14:54 +0800, Tony Lu wrote: > On Thu, Feb 17, 2022 at 12:33:06PM +0100, Niklas Schnelle wrote: > > On Tue, 2021-12-28 at 21:06 +0800, Tony Lu wrote: > > ---8<--- > > Hi Tony, > > > > I'm having a bit of trouble getting this to work for me and was > > wondering if you could test my scenario or help me figure out what's > > wrong. > > > > I'm using network namespacing to be able to test traffic between two > > VFs of the same card/port with a single Linux system. By having one VF > > in each of a client and server namespace, traffic doesn't shortcut via > > loopback. This works great for TCP and with "rdma system set netns > > exclusive" I can also verify that RDMA with "qperf -cm1 ... rc_bw" only > > works once the respective RDMA device is also added to each namespace. > > > > When I try the same with SMC-R I tried: > > > > ip netns exec server smc_run qperf & > > ip netns exec client smc_run qperf <ip_server> tcp_bw > > > > With that however I only see fallback TCP connections in "ip netns exec > > client watch smc_dbg". It doesn't seem to be an "smc_dbg" problem > > either since the performance with and without smc_run is the same. I > > also do have the same PNET_ID set on the interfaces. > > Hi Niklas, > > I understood your problem. This connection falls back to TCP for unknown > reasons. You can find out the fallback reason of this connection. It can > help us find out the root cause of fallbacks. For example, > if SMC_CLC_DECL_MEM (0x01010000) is occurred in this connection, it > means that there is no enough memory (smc_init_info, sndbuf, RMB, > proposal buf, clc msg). Regarding fallback reason. It seems to be that the RDMA device is not found (0x03030000) in smd_dbg on I see the following lines: Server: State UID Inode Local Address Peer Address Intf Mode Shutd Token Sndbuf .. LISTEN 00000 0103804 0.0.0.0:37373 ACTIVE 00000 0112895 ::ffff:10.10.93..:46093 ::ffff:10.10.93..:54474 0000 TCP 0x03030000 ACTIVE 00000 0112701 ::ffff:10.10.93..:19765 ::ffff:10.10.93..:51934 0000 TCP 0x03030000 LISTEN 00000 0112699 0.0.0.0:19765 Client: State UID Inode Local Address Peer Address Intf Mode Shutd Token Sndbuf ... ACTIVE 00000 0116203 10.10.93.11:54474 10.10.93.12:46093 0000 TCP 0x05000000/0x03030000 ACTIVE 00000 0116201 10.10.93.11:51934 10.10.93.12:19765 0000 TCP 0x05000000/0x03030000 However this doesn't match what I'm seeing in the other commands below > > Before you giving out the fallback reason, based on your environment, > this are some potential possibilities. You can check this list: > > - RDMA device availability in netns. Run "ip netns exec server rdma dev" > to check RDMA device in both server/client. If exclusive mode is setted, > it should have different devices in different netns. I get the following output that looks as expected to me: Server: 2: roceP9p0s0: node_type ca fw 14.25.1020 node_guid 1d82:ff9b:1bfe:2c28 sys_image_guid 282c:001b:9b03:9803 Client: 4: roceP11p0s0: node_type ca fw 14.25.1020 node_guid 0982:ff9b:63fe:64e7 sys_image_guid e764:0063:9b03:9803 > - SMC-R device availability in netns. Run "ip netns exec server smcr d" > to check SMC device available list. Only if we have eth name in the > list, it can access by this netns. smc-tools matches ethernet NIC and > RDMA device, it can only find the name of eth nic in this netns, so > there is no name if this eth nic doesn't belong to this netns. > > Net-Dev IB-Dev IB-P IB-State Type Crit #Links PNET-ID > mlx5_0 1 ACTIVE RoCE_Express2 No 0 > eth2 mlx5_1 1 ACTIVE RoCE_Express2 No 0 > > This output shows we have ONE available RDMA device in this netns. Here too things look good to me: Server: Net-Dev IB-Dev IB-P IB-State Type Crit #Links PNET-ID ... roceP12p 1 ACTIVE RoCE_Express2 No 0 NET26 roceP11p 1 ACTIVE RoCE_Express2 No 0 NET25 ens2076 roceP9p0 1 ACTIVE RoCE_Express2 No 0 NET25 Client: Net-Dev IB-Dev IB-P IB-State Type Crit #Links PNET-ID ... roceP12p 1 ACTIVE RoCE_Express2 No 0 NET26 ens1296 roceP11p 1 ACTIVE RoCE_Express2 No 0 NET25 roceP9p0 1 ACTIVE RoCE_Express2 No 0 NET25 And I again confirmed that a pure RDMA workload ("qperf -cm1 ... rc_bw") works with the RDMA namespacing set to exclusive but only if I add the RDMA devices to the namespaces. I do wonder why the other RDMA devices are still visible in the above output though? > - Misc checks, such as memory usage, loop back connection and so on. > Also, you can check dmesg for device operations if you moved netns of > RDMA device. Every device's operation will log in dmesg. > > # SMC module init, adds two RDMA device. > [ +0.000512] smc: adding ib device mlx5_0 with port count 1 > [ +0.000534] smc: ib device mlx5_0 port 1 has pnetid > [ +0.000516] smc: adding ib device mlx5_1 with port count 1 > [ +0.000525] smc: ib device mlx5_1 port 1 has pnetid > > # Move one RDMA device to another netns. > [Feb21 14:16] smc: removing ib device mlx5_1 > [ +0.015723] smc: adding ib device mlx5_1 with port count 1 > [ +0.000600] smc: ib device mlx5_1 port 1 has pnetid There is no memory pressure and SMC-R between two systems works. I also see the smc add/remove messages in dmesg as you describe: smc: removing ib device roceP11p0s0 smc: adding ib device roceP11p0s0 with port count 1 smc: ib device roceP11p0s0 port 1 has pnetid NET25 smc: removing ib device roceP9p0s0 smc: adding ib device roceP9p0s0 with port count 1 smc: ib device roceP9p0s0 port 1 has pnetid NET25 mlx5_core 000b:00:00.0 ens1296: Link up mlx5_core 0009:00:00.0 ens2076: Link up IPv6: ADDRCONF(NETDEV_CHANGE): ens2076: link becomes ready smc: removing ib device roceP11p0s0 smc: adding ib device roceP11p0s0 with port count 1 smc: ib device roceP11p0s0 port 1 has pnetid NET25 mlx5_core 000b:00:00.0 ens1296: Link up mlx5_core 0009:00:00.0 ens2076: Link up smc: removing ib device roceP9p0s0 smc: adding ib device roceP9p0s0 with port count 1 smc: ib device roceP9p0s0 port 1 has pnetid NET25 IPv6: ADDRCONF(NETDEV_CHANGE): ens1296: link becomes ready (The PCI addresses and resulting names are normal for s390) One thing I notice is that you don't seem to have a pnetid set in your output, did you redact those or are you dealing differently with PNETIDs? Maybe there is an issue with matching PNETIDs betwen RDMA devices and network devices when namespaced? I also tested with smc_chk instead of qperf to make sure it's not a problem with LD_PRELOAD or anything like that. With that it simply doesn't connect.