On Thursday, May 15, 2014 02:33:07 PM Eduardo Valentin wrote: > Hello Amit, > > > On Thu, May 08, 2014 at 08:07:56PM +0530, Amit Daniel Kachhap wrote: > > This patch is in preparation to add notfication support for cpufrequency > > cooling changes. This change also removes the unnecessary exposing of > > internal housekeeping structure via thermal_cooling_device->devdata to the > > users of cpufreq cooling APIs. > > > > Signed-off-by: Amit Daniel Kachhap <amit.daniel@xxxxxxxxxxx> > > --- > > drivers/thermal/cpu_cooling.c | 79 +++++++++++++++---- > > drivers/thermal/db8500_cpufreq_cooling.c | 2 +- > > drivers/thermal/samsung/exynos_thermal_common.c | 2 +- > > drivers/thermal/ti-soc-thermal/ti-thermal-common.c | 2 +- > > include/linux/cpu_cooling.h | 5 +- > > 5 files changed, 68 insertions(+), 22 deletions(-) > > > > diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c > > index 4246262..21f44d4 100644 > > --- a/drivers/thermal/cpu_cooling.c > > +++ b/drivers/thermal/cpu_cooling.c > > @@ -50,16 +50,18 @@ struct cpufreq_cooling_device { > > unsigned int cpufreq_state; > > unsigned int cpufreq_val; > > struct cpumask allowed_cpus; > > + struct list_head node; > > }; > > static DEFINE_IDR(cpufreq_idr); > > static DEFINE_MUTEX(cooling_cpufreq_lock); > > > > -static unsigned int cpufreq_dev_count; > > - > > /* notify_table passes value to the CPUFREQ_ADJUST callback function. */ > > #define NOTIFY_INVALID NULL > > static struct cpufreq_cooling_device *notify_device; > > > > +/* A list to hold all the cpufreq cooling devices registered */ > > +static LIST_HEAD(cpufreq_cooling_list); > > + > > /** > > * get_idr - function to get a unique id. > > * @idr: struct idr * handle used to create a id. > > @@ -357,12 +359,23 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, > > static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, > > unsigned long *state) > > { > > - struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; > > - struct cpumask *mask = &cpufreq_device->allowed_cpus; > > + struct cpufreq_cooling_device *cpufreq_device = NULL; > > + struct cpumask *mask = NULL; > > unsigned int cpu; > > unsigned int count = 0; > > int ret; > > > > + mutex_lock(&cooling_cpufreq_lock); > > + list_for_each_entry(cpufreq_device, &cpufreq_cooling_list, node) > > + if (cpufreq_device->cool_dev == cdev) > > + break; > > + mutex_unlock(&cooling_cpufreq_lock); > > + if (!cpufreq_device) { > > + /* Cooling device pointer not found */ > > + return -EINVAL; > > + } > > + > > + mask = &cpufreq_device->allowed_cpus; > > cpu = cpumask_any(mask); > > > > ret = get_property(cpu, 0, &count, GET_MAXL); > > @@ -386,7 +399,17 @@ static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, > > static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, > > unsigned long *state) > > { > > - struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; > > + struct cpufreq_cooling_device *cpufreq_device = NULL; > > + > > + mutex_lock(&cooling_cpufreq_lock); > > + list_for_each_entry(cpufreq_device, &cpufreq_cooling_list, node) > > + if (cpufreq_device->cool_dev == cdev) > > + break; > > + mutex_unlock(&cooling_cpufreq_lock); > > + if (!cpufreq_device) { > > + /* Cooling device pointer not found */ > > + return -EINVAL; > > + } > > > > *state = cpufreq_device->cpufreq_state; > > > > @@ -406,7 +429,17 @@ static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, > > static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, > > unsigned long state) > > { > > - struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; > > + struct cpufreq_cooling_device *cpufreq_device = NULL; > > + > > + mutex_lock(&cooling_cpufreq_lock); > > + list_for_each_entry(cpufreq_device, &cpufreq_cooling_list, node) > > + if (cpufreq_device->cool_dev == cdev) > > + break; > > + mutex_unlock(&cooling_cpufreq_lock); > > + if (!cpufreq_device) { > > + /* Cooling device pointer not found */ > > + return -EINVAL; > > + } > > > > return cpufreq_apply_cooling(cpufreq_device, state); > > } > > @@ -427,6 +460,7 @@ static struct notifier_block thermal_cpufreq_notifier_block = { > > * __cpufreq_cooling_register - helper function to create cpufreq cooling device > > * @np: a valid struct device_node to the cooling device device tree node > > * @clip_cpus: cpumask of cpus where the frequency constraints will happen. > > + * @devdata: driver data pointer > > * > > * This interface function registers the cpufreq cooling device with the name > > * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq > > @@ -438,7 +472,7 @@ static struct notifier_block thermal_cpufreq_notifier_block = { > > */ > > static struct thermal_cooling_device * > > __cpufreq_cooling_register(struct device_node *np, > > - const struct cpumask *clip_cpus) > > + const struct cpumask *clip_cpus, void *devdata) > > { > > struct thermal_cooling_device *cool_dev; > > struct cpufreq_cooling_device *cpufreq_dev = NULL; > > @@ -477,7 +511,7 @@ __cpufreq_cooling_register(struct device_node *np, > > snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d", > > cpufreq_dev->id); > > > > - cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev, > > + cool_dev = thermal_of_cooling_device_register(np, dev_name, devdata, > > &cpufreq_cooling_ops); > > if (IS_ERR(cool_dev)) { > > release_idr(&cpufreq_idr, cpufreq_dev->id); > > @@ -489,10 +523,11 @@ __cpufreq_cooling_register(struct device_node *np, > > mutex_lock(&cooling_cpufreq_lock); > > > > /* Register the notifier for first cpufreq cooling device */ > > - if (cpufreq_dev_count == 0) > > + if (list_empty(&cpufreq_cooling_list)) > > cpufreq_register_notifier(&thermal_cpufreq_notifier_block, > > CPUFREQ_POLICY_NOTIFIER); > > - cpufreq_dev_count++; > > + > > + list_add(&cpufreq_dev->node, &cpufreq_cooling_list); > > > > mutex_unlock(&cooling_cpufreq_lock); > > > > @@ -502,6 +537,7 @@ __cpufreq_cooling_register(struct device_node *np, > > /** > > * cpufreq_cooling_register - function to create cpufreq cooling device. > > * @clip_cpus: cpumask of cpus where the frequency constraints will happen. > > + * @devdata: driver data pointer > > * > > * This interface function registers the cpufreq cooling device with the name > > * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq > > @@ -511,9 +547,9 @@ __cpufreq_cooling_register(struct device_node *np, > > * on failure, it returns a corresponding ERR_PTR(). > > */ > > struct thermal_cooling_device * > > -cpufreq_cooling_register(const struct cpumask *clip_cpus) > > +cpufreq_cooling_register(const struct cpumask *clip_cpus, void *devdata) > > { > > - return __cpufreq_cooling_register(NULL, clip_cpus); > > + return __cpufreq_cooling_register(NULL, clip_cpus, devdata); > > } > > EXPORT_SYMBOL_GPL(cpufreq_cooling_register); > > > > @@ -537,7 +573,7 @@ of_cpufreq_cooling_register(struct device_node *np, > > if (!np) > > return ERR_PTR(-EINVAL); > > > > - return __cpufreq_cooling_register(np, clip_cpus); > > + return __cpufreq_cooling_register(np, clip_cpus, NULL); > > } > > EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); > > > > @@ -554,17 +590,26 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) > > if (!cdev) > > return; > > > > - cpufreq_dev = cdev->devdata; > > mutex_lock(&cooling_cpufreq_lock); > > - cpufreq_dev_count--; > > + > > + list_for_each_entry(cpufreq_dev, &cpufreq_cooling_list, node) > > + if (cpufreq_dev->cool_dev == cdev) > > + break; > > + > > + if (!cpufreq_dev) { > > + /* Cooling device pointer not found */ > > + mutex_unlock(&cooling_cpufreq_lock); > > + return; > > + } > > Because you are adding several times the same code to search through > your list of cdevs, I recommend adding at least a helper function to > perform this recurring operation. Violently agreed. -- I speak only for myself. Rafael J. Wysocki, Intel Open Source Technology Center.