Hi, in addition to the constant flickering when running on AC, there is a more "high frequency" flickering immediately after plugging in the AC: For some 5 to 10 seconds, the battery appears and disappears (according to upower) around once per second. There's also a short moment without battery after plugging out the AC. All this is gone after going to a kernel version without this patch applied. I did not notice unusual high CPU usage of upower on my system, however I noticed disc activity - according to iotop, upower is writing several MiB of data per minute to /var/lib/upower/ where it keeps some battery statistics. I do not know whether this is out of the ordinary. Kind regards, Ralf On Tuesday 01 May 2012 21:14:08 Jonathan Nieder wrote: > (cc-ing Andy) > > Adrian Fita wrote: > > Also, searching on Google after "upowerd device > > removed:/org/freedesktop/UPower/devices/battery_BAT0", reveals much > > more bug reports with the exact issue. > > Thanks. That confirms the high CPU consumption in upowerd --- > see [1], for example. > > [1] https://bugs.launchpad.net/ubuntu/+source/linux/+bug/987807 _______________________________________________ linux-pm mailing list linux-pm@xxxxxxxxxxxxxxxxxxxxxxxxxx https://lists.linuxfoundation.org/mailman/listinfo/linux-pm