Got it. Bjorn, thanks. Jay On 2020/4/21 1:47, Bjorn Helgaas wrote: > Hi Jay, thanks for taking a look at this! > > On Mon, Apr 20, 2020 at 09:21:27AM -0700, Sean V Kelley wrote: >> On 18 Apr 2020, at 1:36, Jay Fang wrote: >>> On 2020/4/15 8:47, Sean V Kelley wrote: >>>> >>>> [1] https://www.computeexpresslink.org/ >>>> >>>> Signed-off-by: Sean V Kelley <sean.v.kelley@xxxxxxxxxxxxxxx> >>>> --- >>>> lib/header.h | 20 +++ >>> >>>> + >>>> +static int >>>> +is_cxl_cap(struct device *d, int where) >>>> +{ >>>> + u32 hdr; >>>> + u16 w; >>>> + >>>> + if (!config_fetch(d, where + PCI_DVSEC_HEADER1, 8)) >>>> + return 0; >>>> + >>>> + /* Check for supported Vendor */ >>>> + hdr = get_conf_long(d, where + PCI_DVSEC_HEADER1); >>>> + w = BITS(hdr, 0, 16); >>>> + if (w != PCI_VENDOR_ID_INTEL) >>> >>> I don't think here checking is quite right. Does only Intel support CXL? >>> Other Vendors should also be considered. >> >> In the absence of currently available hardware, I was attempting to limit >> false positive noise. I’m happy to avoid the check on the vendor if there >> were to exist a definitive supported list. Bjorn suggested that I check for >> vendor ID with DVSEC ID for now. As hardware enters the market, I can >> surely revise this with an update when the CXL group publishes a list. > > The Vendor ID check cannot be avoided. Vendor IDs are allocated by > the PCI-SIG, but the DVSEC ID is vendor-defined so there cannot be a > global "CXL capability" DVSEC ID. > > CXL *could* work through the PCI-SIG and define a new CXL Extended > Capability that could make this generic. But apparently they've > chosen to use the DVSEC mechanism instead. > >>>> + /* Check for Designated Vendor-Specific ID */ >>>> + hdr = get_conf_long(d, where + PCI_DVSEC_HEADER2); >>>> + w = BITS(hdr, 0, 16); >>>> + if (w == PCI_DVSEC_ID) > > However, this is slightly wrong. The name "PCI_DVSEC_ID" implies that > there can only be one DVSEC ID and it is vendor-independent, but > neither is true. > > This value is allocated by Intel, so we must check for the Intel > Vendor ID first. And Intel may define several DVSEC capabilities for > different purposes, so the name should also mention CXL. > > So this should be "PCI_DVSEC_INTEL_CXL" or something similar. > > But that doesn't mean other vendors need to define their own DVSEC > IDs for CXL. The spec (PCIe r5.0, sec 7.9.6) says: > > [The DVSEC Capability] allows PCI Express component vendors to use > the Extended Capability mechanism to expose vendor-specific > registers that can be present in components by a variety of > vendors. > > Any vendor that implements this CXL DVSEC the same way Intel does can > tag it with PCI_VENDOR_ID_INTEL and PCI_DVSEC_INTEL_CXL. > > Note that there are two types of vendor-specific capabilities: > > 1) Vendor-Specific Extended Capability (VSEC). The structure and > definition are defined by the *Function* Vendor ID (from offset 0 in > config space) and the VSEC ID in the capability. > > 2) Designated Vendor-Specific Extended Capability (DVSEC). The > structure and definition are defined by the *DVSEC* Vendor ID (from > the DVSEC capability, *not* the vendor of the Function) and the > DVSEC ID in the capability. > > This CXL capability is the latter, of course. > > Bjorn > > . >