On Mon, 2019-11-11 at 05:21:28 UTC, Tyrel Datwyler wrote: > The ibm,drc-info property is an array property that contains drc-info > entries such that each entry is made up of 2 string encoded elements > followed by 5 int encoded elements. The of_read_drc_info_cell() > helper contains comments that correctly name the expected elements > and their encoding. However, the usage of of_prop_next_string() and > of_prop_next_u32() introduced a subtle skippage of the first u32. > This is a result of of_prop_next_string() returning a pointer to the > next property value which is not a string, but actually a (__be32 *). > As, a result the following call to of_prop_next_u32() passes over the > current int encoded value and actually stores the next one wrongly. > > Simply endian swap the current value in place after reading the first > two string values. The remaining int encoded values can then be read > correctly using of_prop_next_u32(). > > Signed-off-by: Tyrel Datwyler <tyreld@xxxxxxxxxxxxx> Series applied to powerpc next, thanks. https://git.kernel.org/powerpc/c/57409d4fb12c185b2c0689e0496878c8f6bb5b58 cheers