On 29 Apr 2014, at 3:20 , Borislav Petkov <bp@xxxxxxx> wrote: > On Tue, Apr 29, 2014 at 09:33:09AM +0200, Andreas Herrmann wrote: >> I am sure, it's because some server systems had MMIO ECS access not >> enabled in BIOS. I can't remember which systems were affected. > > Ok, now AMD people: what's the story with IO ECS, can we assume that on > everything after F10h, BIOS has a sensible MCFG and we can limit this to > F10h only? I like Bjorn's idea but we need to make sure a working MCFG > is ubiquitous. > > Which begs the real question: Suravee, why are you even touching IO ECS > provided F15h and later have a MCFG? Or, do they? > Our experience with this is that Fam10h and later have a very well working MCFG setup, earlier generations not so much (hence IO ECS was needed). Cheers, Steffen -- To unsubscribe from this list: send the line "unsubscribe linux-pci" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html