On 2024/12/11 1:33, Bjorn Helgaas wrote:
On Mon, Dec 09, 2024 at 03:19:38PM +0800, Chen Wang wrote:
Add binding for Sophgo SG2042 PCIe host controller.
+ sophgo,pcie-port:
This is just an index, isn't it? I don't see why it should include
"sophgo" unless it encodes something sophgo-specific.
I previously understood that if it is not a standard attribute defined
by the dts schema, such as pcie-port, which is defined by me, it must be
prefixed with vendor. Is that right?
+ $ref: /schemas/types.yaml#/definitions/uint32
+ description: |
+ SG2042 uses Cadence IP, every IP is composed of 2 cores(called link0
Add space before "(". More instances below.
ok
+ & link1 as Cadence's term). "sophgo,pcie-port" is used to identify which
+ core/link the pcie host controller node corresponds to.
s/pcie/PCIe/ for consistency in the text. More instances below.
ok
+ The Cadence IP has two modes of operation, selected by a strap pin.
+
+ In the single-link mode, the Cadence PCIe core instance associated
+ with Link0 is connected to all the lanes and the Cadence PCIe core
+ instance associated with Link1 is inactive.
+
+ In the dual-link mode, the Cadence PCIe core instance associated
+ with Link0 is connected to the lower half of the lanes and the
+ Cadence PCIe core instance associated with Link1 is connected to
+ the upper half of the lanes.
I assume this means there are two separate Root Ports, one for Link0
and a second for Link1?
Yes. So the naming of pcie_rcX is wrong, I will correct it, thanks.
+ SG2042 contains 2 Cadence IPs and configures the Cores as below:
+
+ +-- Core(Link0) <---> pcie_rc0 +-----------------+
+ | | |
+ Cadence IP 1 --+ | cdns_pcie0_ctrl |
+ | | |
+ +-- Core(Link1) <---> disabled +-----------------+
+
+ +-- Core(Link0) <---> pcie_rc1 +-----------------+
+ | | |
+ Cadence IP 2 --+ | cdns_pcie1_ctrl |
+ | | |
+ +-- Core(Link1) <---> pcie_rc2 +-----------------+
+
+ pcie_rcX is pcie node ("sophgo,sg2042-pcie-host") defined in DTS.
+ cdns_pcie0_ctrl is syscon node ("sophgo,sg2042-pcie-ctrl") defined in DTS
+
+ cdns_pcieX_ctrl contains some registers shared by pcie_rcX, even two
+ RC(Link)s may share different bits of the same register. For example,
+ cdns_pcie1_ctrl contains registers shared by link0 & link1 for Cadence IP 2.
An RC doesn't have a Link. A Root Port does.
+ "sophgo,pcie-port" is defined to flag which core(link) the rc maps to, with
+ this we can know what registers(bits) we should use.
+
+ sophgo,syscon-pcie-ctrl:
+ $ref: /schemas/types.yaml#/definitions/phandle
+ description:
+ Phandle to the PCIe System Controller DT node. It's required to
+ access some MSI operation registers shared by PCIe RCs.
I think this probably means "shared by PCIe Root Ports", not RCs.
It's unlikely that this hardware has multiple Root Complexes.
Ok, I will fix this.
+required:
+ - compatible
+ - reg
+ - reg-names
+ - vendor-id
+ - device-id
+ - sophgo,syscon-pcie-ctrl
+ - sophgo,pcie-port
It looks like vendor-id and device-id apply to PCI devices, i.e.,
things that will show up in lspci, I assume Root Ports in this case.
Can we make this explicit in the DT, e.g., something like this?
pcie@62000000 {
compatible = "sophgo,sg2042-pcie-host";
port0: pci@0,0 {
vendor-id = <0x1f1c>;
device-id = <0x2042>;
};
Sorry, I don't understand your meaning very well. Referring to the
topology diagram I drew above, is it okay to write DTS as follows?
pcie@7060000000 {
compatible = "sophgo,sg2042-pcie-host";
...... // other properties
pci@0,0 {
vendor-id = <0x1f1c>;
device-id = <0x2042>;
};
}
pcie@7062000000 {
compatible = "sophgo,sg2042-pcie-host";
...... // other properties
pci@0,0 {
vendor-id = <0x1f1c>;
device-id = <0x2042>;
};
}
pcie@7062800000 {
compatible = "sophgo,sg2042-pcie-host";
...... // other properties
pci@1,0 {
vendor-id = <0x1f1c>;
device-id = <0x2042>;
};
}
And with this change, I can drop the “pcie-port”property and use the
port name to figure out the port number, right?
+additionalProperties: true
+
+examples:
+ - |
+ #include <dt-bindings/interrupt-controller/irq.h>
+
+ pcie@62000000 {
+ compatible = "sophgo,sg2042-pcie-host";
+ device_type = "pci";
+ reg = <0x62000000 0x00800000>,
+ <0x48000000 0x00001000>;
+ reg-names = "reg", "cfg";
+ #address-cells = <3>;
+ #size-cells = <2>;
+ ranges = <0x81000000 0 0x00000000 0xde000000 0 0x00010000>,
+ <0x82000000 0 0xd0400000 0xd0400000 0 0x0d000000>;
+ bus-range = <0x80 0xbf>;
+ vendor-id = <0x1f1c>;
+ device-id = <0x2042>;
+ cdns,no-bar-match-nbits = <48>;
+ sophgo,pcie-port = <0>;
+ sophgo,syscon-pcie-ctrl = <&cdns_pcie1_ctrl>;
+ msi-parent = <&msi_pcie>;
+ msi_pcie: msi {
+ compatible = "sophgo,sg2042-pcie-msi";
+ msi-controller;
+ interrupt-parent = <&intc>;
+ interrupts = <123 IRQ_TYPE_LEVEL_HIGH>;
+ interrupt-names = "msi";
+ };
+ };
--
2.34.1