On Wed, Nov 06, 2024 at 12:13:09PM -0500, Frank Li wrote: > On Wed, Nov 06, 2024 at 10:36:42AM +0100, Niklas Cassel wrote: > > On Wed, Nov 06, 2024 at 10:15:27AM +0100, Niklas Cassel wrote: > > > > > > I do get a domain, but I do not get any IRQ on the EP side when the RC side is > > > writing the doorbell (as part of pcitest -B), > > > > > > [ 7.978984] pci_epc_alloc_doorbell: num_db: 1 > > > [ 7.979545] pci_epf_test_bind: doorbell_addr: 0x40 > > > [ 7.979978] pci_epf_test_bind: doorbell_data: 0x0 > > > [ 7.980397] pci_epf_test_bind: doorbell_bar: 0x1 > > > [ 21.114613] pci_epf_enable_doorbell db_bar: 1 > > > [ 21.115001] pci_epf_enable_doorbell: doorbell_addr: 0xfe650040 > > > [ 21.115512] pci_epf_enable_doorbell: phys_addr: 0xfe650000 > > > [ 21.115994] pci_epf_enable_doorbell: success > > > > > > # cat /proc/interrupts | grep epc > > > 117: 0 0 0 0 0 0 0 0 ITS-pMSI-a40000000.pcie-ep 0 Edge pci-epc-doorbell0 > > > > > > Even if I try to write the doorbell manually from EP side using devmem: > > > > > > # devmem 0xfe670040 32 1 > > > > Sorry, this should of course have been: > > # devmem 0xfe650040 32 1 > > Thank you test it. You can't write it at EP side. ITS identify the bus > master. master ID (streamid) of CPU is the diffference with PCI master's > ID (streamid). You set msi-parent = <&its0 0x0000>, not sure if 0x0000 is > validate stream. I see, this makes sense since the ITS converts BDF to an MSI specifier. > > You have to run at RC side, "devmem (Bar1+0x40) 32 0". So PCIe EP > controller can use EP streamid. > > some system need special register to config stream id, you can refer host > side's settings. > <&its0 0x0000>, second argument is your PCIe controller's stream ID. You > can ref RC side. The RC node looks like this: msi-map = <0x0000 &its1 0x0000 0x1000>; So it does indeed use 0x0 as the MSI specifier. > > > > > Considering that the RC node is using &its1, that is probably > > also what should be used in the EP node when running the controller > > in EP mode instead of RC mode. > > Generally, RC node should use smmu-map, instead &its1. Or your PCI > controller direct use 16bit RID as streamid. smmu-map? Do you mean iommu-map? I don't see why we would need to have the SMMU enabled to use ITS. The iommu is currently disabled on my platform. I did enable the iommu, and all BAR tests, read tests, write tests, and copy tests pass. However I get an iommu error when the RC is writing the doorbell. Perhaps you need to do dma_map_single() on the address that you are setting the inbound address translation to? Without the IOMMU, if I modify pci_endpoint_test.c to not send the DISABLE_DOORBELL command on error (so that EP side still has DB enabled), I can read all BARs except BAR1 (which was used for the doorbell): [ 21.077417] pci 0000:01:00.0: BAR 0 [mem 0xf0300000-0xf03fffff]: assigned [ 21.078029] pci 0000:01:00.0: BAR 1 [mem 0xf0400000-0xf04fffff]: assigned [ 21.078640] pci 0000:01:00.0: BAR 2 [mem 0xf0500000-0xf05fffff]: assigned [ 21.079250] pci 0000:01:00.0: BAR 3 [mem 0xf0600000-0xf06fffff]: assigned [ 21.079860] pci 0000:01:00.0: BAR 5 [mem 0xf0700000-0xf07fffff]: assigned # pcitest -B [ 25.156623] COMMAND_ENABLE_DOORBELL complete - status: 0x440 [ 25.157131] db_bar: 1 addr: 0x40 data: 0x0 [ 25.157501] setting irq_type to: 1 [ 25.157802] writing: 0x0 to offset: 0x40 in BAR: 1 [ 35.300676] we wrote to the BAR, status is now: 0x0 status is not updated after writing to DB, and /proc/interrupts on EP side is not incrementing. # devmem 0xf0300000 0x00000000 # devmem 0xf0400040 0xFFFFFFFF # devmem 0xf0500000 0x00000000 # devmem 0xf0600000 0x00000000 # devmem 0xf0700000 0x00000000 So there does seem to be something wrong with the inbound translation, at least when testing on rk3588 which only uses 1MB fixed size BARs: https://github.com/torvalds/linux/blob/v6.12-rc6/drivers/pci/controller/dwc/pcie-dw-rockchip.c#L276-L281 You also didn't answer which imx platform that you are using to test this, I don't see a single imx platform that specifies "msi-parent". Kind regards, Niklas