> On 7/23/2024 4:04 PM, Zhou Shengqing wrote: > >> I think this has potential. Can you include a more complete citation > >> for the Intel spec? Complete name, document number if available, > >> revision, section? Hopefully it's publically available? > > Most of intel CPU EDS specs are under NDA. But you can refer to > > https://www.intel.com/content/dam/www/public/us/en/documents/datasheets/xeon-e5-v2-datasheet-vol-2.pdf > > keyword:"EN1K". > > ... > > > > while ((d = pci_get_device(PCI_VENDOR_ID_INTEL, 0x09a2, d))) { > > if (pci_domain_nr(d->bus) == pci_domain_nr(dev->bus)) { > > Perhaps it is enough to check if the 0x09a2 VT-d and the rootport are on the smae bus > e.g. On my SPR, domain 0000 Thank you for your comment. Do you mean it shoud be like this? while ((d = pci_get_device(PCI_VENDOR_ID_INTEL, 0x09a2, d))) { if (d->bus->number == dev->bus->number) { pci_read_config_word(d, 0x1c0, &en1k); if (en1k & 0x4) { pci_info(dev, "1K I/O windows enabled per %s EN1K setting\n", pci_name(d)); dev->io_window_1k = 1; } } } > > 00:00.0 System peripheral: Intel Corporation Device 09a2 (rev 20) > 00:0f.0 PCI bridge: Intel Corporation Device 1bbf (rev 10) (prog-if 00 [Normal decode]) > > > 15:00.0 System peripheral: Intel Corporation Device 09a2 (rev 20) > 15:01.0 PCI bridge: Intel Corporation Device 352a (rev 04) (prog-if 00 [Normal decode]) > > and if you check domain number only, they might sit on different bus, perhaps that > would make thing complex, could you make sure the VT-d is on the upstream bus of the > bridge ? I checked it on ICX SPR EMR GNR, VT-d is always on the same bus with root port, and VT-d device and function number is always 0. Please let me know if further modifications are needed. > > Thanks, > Ethan