On 5/31/24 16:14, Krishna Kumar wrote: > On 5/23/24 20:22, Krishna Kumar wrote: >> >> Hi Oliver, >> >> Thanks for your suggestions. Pls find my response: >> >> On 5/20/24 20:29, Oliver O'Halloran wrote: >>> On Fri, May 17, 2024 at 9:15 PM krishna kumar <krishnak@xxxxxxxxxxxxx> wrote: >>>>> Uh, if I'm reading this right it looks like your "slot" C5 is actually >>>>> the PCIe switch's internal bus which is definitely not hot pluggable. >>>> It's a hotplug slot. Please see the snippet below: >>>> >>>> :~$ sudo lspci -vvv -s 0004:02:00.0 | grep --color HotPlug >>>> SltCap: AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise- >>>> :~$ >>>> >>>> :~$ sudo lspci -vvv -s 0004:02:01.0 | grep --color HotPlug >>>> SltCap: AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise- >>>> :~$ >>>> >>>> :~$ sudo lspci -vvv -s 0004:02:02.0 | grep --color HotPlug >>>> SltCap: AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise- >>>> :~$ >>>> >>>> :~$ sudo lspci -vvv -s 0004:02:03.0 | grep --color HotPlug >>>> SltCap: AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise- >>>> :~$ >>> All this is showing is that the switch downstream ports on bus 0004:02 >>> have a slot capability. I already know that (see what I said >>> previously about physical links). The fact the downstream ports have a >>> slot capability also has absolutely nothing to do with anything I was >>> saying. Look at the lspci output for 0004:01:00.0 which is the >>> switch's upstream port. The upstream port device will not have a slot >>> capability because it's a bridge into the virtual PCI bus that is >>> internal to the switch. >> Let me try to understand your suggestion and what needs to be done now: >> >> lspci -nn snippet in current scenario: >> >> 0004:01:00.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052] >> 0004:01:00.1 Memory controller [0580]: PMC-Sierra Inc. Device [11f8:4052] >> 0004:02:00.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052] >> 0004:02:01.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052] >> 0004:02:02.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052] >> 0004:02:03.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052] >> >> lspci -tv snippet in current scenario: >> >> +-[0001:00]---00.0-[01-0a]--+-00.0-[02-0a]--+-00.0-[03-07]-- >> | | +-01.0-[08]--+-00.0 Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe >> | | | +-00.1 Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe >> | | | +-00.2 Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe >> | | | \-00.3 Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe >> | | +-02.0-[09]----00.0 Broadcom / LSI SAS3216 PCI-Express Fusion-MPT SAS-3 >> | | \-03.0-[0a]----00.0 IBM PCI-E IPR SAS Adapter (ASIC) >> | \-00.1 PMC-Sierra Inc. Device 4052 >> >> C5 bus address: >> >> [root@ltczzess2-lp1 ~]# cat /sys/bus/pci/slots/C5/address >> 0004:02:00 >> [root@ltczzess2-lp1 ~]# >> >> 0004:01:00.0 doesn't have hotplug capability but 0004:02:00.0 does >> have this capability. Below snippet tells about this: >> >> [root@ltczzess2-lp1 ~]# sudo lspci -vvv -s 0004:01:00.0 | grep --color HotPlug >> [root@ltczzess2-lp1 ~]# >> [root@ltczzess2-lp1 ~]# sudo lspci -vvv -s 0004:02:00.0 | grep --color HotPlug >> SltCap: AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise- >> [root@ltczzess2-lp1 ~]# >> >> In Function - pnv_php_register_one() is responsible for slot creation from >> hotplug capable device node: >> >> Below is the current code that does check the device node for hot plug >> capability and takes the decision >> >> /* Check if it's hotpluggable slot */ >> ret = of_property_read_u32(dn, "ibm,slot-pluggable", &prop32); >> if (ret || !prop32){ >> return -ENXIO; >> } >> >> Its obvious that 0004:01:00.0 does not get above criteria fulfilled but >> 0004:02:00.0 does, so is the current behavior (Upstream port is not became >> C5 slot but downstream port became C5 slot). >> >> I am summarizing your suggested changes. Please let >> me know if I've got it right: >> >> 1. Do you want me to modify the code so that the C5 >> device-bdf and bus-address become 0004:01:00/0004:01 >> instead of 0004:02:00/0004:01? >> >> 2. When performing a hot-unplug operation on C5, >> should all devices from 0004:01 be removed? And >> should all devices from 0004:02 also be removed? >> I think the answer is yes, but please confirm. >> >> 3. When performing a hot-plug operation on C5, >> should all the devices removed earlier from 0004:01 >> and 0004:02 be re-attached? >> >> 4. Will there be any PCIe topology changes in this workflow? >> >> Once you confirm the above requirements, we can discuss >> how to proceed further. >> I have some follow up questions from your last mail and I am >> putting these questions in below paragraphs as inline statements. >> It will confirm me if we should do above things or not. >> >> >>>> It seems like your explanation about the missing 0004:01:00.0 may be >>>> correct and could be due to a firmware bug. However, the scope of this >>>> patch does not relate to this issue. Additionally, if it starts with >>>> 0004:01:00.0 to 0004:01:03.0, the behavior of hot-unplug and hot-plug >>>> operations will remain inconsistent. This patch aims to address the >>>> inconsistent behavior of hot-unplug and hot-plug. >>>> >>>> *snip* >>>> >>>>> It might be worth adding some logic to pnv_php to verify the PCI >>>>> bridge upstream of the slot actually has the PCIe slot capability to >>>>> guard against this problem. >>>> We can have a look at this problem in another patch. >>> The point of this series is to fix the behaviour of pnv_php, is it >>> not? >> Yes and we will do necessary things. >> >>> Powering off a PCI(e) slot is supposed to render it safe to >>> remove the card in that slot. >> Do you mean physical-removal of the device after power-off ? >> >>> Currently if you "power off" C5, the >>> kernel is still going to have active references to the switch's >>> upstream port device (at 0004:01:00.0) and the switch management >>> function (at 0004:01:00.1). >> Yes, since we are only operating on the downstream port of C5, >> upstream ports' reference to the kernel will remain the same. >> >>> If the kernel has active references to PCI >>> devices physically located in the slot we supposedly powered off, then >>> the hotplug driver isn't doing its job. >> We have only powered off the downstream ports, not the upstream port. >> The upstream port will remain powered on. Do you mean to say that it >> will cause a problem if we physically remove the device while the >> upstream port is powered on and the downstream port is powered off? >> Will it cause a kernel crash? Is this the reason for designating the >> upstream port as a C5 slot and performing a hot-plug operation on it? >> Is it correct to select a device port that is not hot-pluggable, >> designate it as a C5 slot, and perform a hot-plug operation on it? >> >> >>> The asymmetry between hot add >>> and removal that you're trying to fix here is a side effect of the >>> fact that pnv_php is advertising the wrong thing as a slot. >> Pnv-php is displaying the information, what it receives from the >> device node property. We will attempt to modify the code >> path that is responsible for this. I am not sure yet what >> additional code is needed for this, but I will figure it >> out. Is it okay to change this code? >> >>> I think >>> you should stop pnv_php from advertising something as a slot when it's >>> not actually a slot because that's the root of all your problems. >> Okay, I am aligned but need some more clarification. Currently, >> we are observing this behavior with the PMC-Sierra bridge. >> Will this behavior occur with all bridges? In other words, >> will the upstream port capability not be hot-pluggable for >> all bridges and switches, and therefore not be considered >> for slot selection? >> >> In a previous email, you mentioned that this problem is due >> to a firmware bug, causing the driver to behave incorrectly >> and advertise the wrong port as a slot. Assuming the firmware >> bug is not present, what will be the behavior? Will there be >> any expected PCI-topology changes in the above "lspci -tv" >> command? Also, if the firmware bug is not present, do we still >> need to make changes to the driver code? >> >> >> Best Regards, >> Krishna > > While I am still waiting for a response on the above points, > I would like to add a few more points here: > > 1. The connection between the upstream and downstream > ports is vendor-specific, and we cannot control this. > > 2. When running "lspci -vvv" on the upstream port, it neither > shows its a slot nor a hotplug slot. This is the reason pnv_php > does not advertise the upstream port as a slot. I have observed > similar behavior for upstream and downstream ports on other > architectures and with other switches as well. > > > Snippet for Upstream Port, showing it is neither a slot nor a hotplug > slot. > > # lspci -vvv -s 0004:01:00.0 | grep -i slot > ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ SlotPowerLimit 0.000W > TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt- > [root@ltczzess2-lp1 ~]# > > # lspci -vvv -s 0004:01:00.0 | grep -i Upstream > Capabilities: [40] Express (v2) Upstream Port, MSI 00 > Retimer- 2Retimers- CrosslinkRes: Upstream Port > ACSCap: SrcValid- TransBlk- ReqRedir+ CmpltRedir+ UpstreamFwd- EgressCtrl- DirectTrans+ > ACSCtl: SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans- > # > > Downstream Port snippet : Its a slot and hotplug slot too. > > # > # lspci -vvv -s 0004:02:00.0 | grep -i slot > Physical Slot: C5 > Capabilities: [40] Express (v2) Downstream Port (Slot+), MSI 00 > TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt- > Slot #1, PowerLimit 0.000W; Interlock- NoCompl+ > # > > # lspci -vvv -s 0004:02:00.0 | grep -i hot > SltCap: AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise- > Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) > # > > 3. The devices are connected to the downstream port, and hotplug > operations should only occur on these ports, not on the upstream port. > > 4. The upstream port and downstream port remain on different buses. > I have observed this behavior with other architectures and switches too. > > 5. Performing a poweroff operation on different ports of the bridge > and the devices behind them does not cause any problems for the > available upstream port. I have not encountered any tests/scenarios > where this could create a problem. > > Taking all of the above points into consideration, I do not see any need > for further code changes in the pnv_php driver regarding this matter. > > I got one more setup having below configuration. I did some experiment and here are my observations - # lspci -tv +-[0033:00]---00.0-[01-17]----00.0-[02-17]--+-01.0-[03-07]-- | +-04.0-[08-0c]-- | +-05.0-[0d]----00.0 Samsung Electronics Co Ltd NVMe SSD Controller PM173X | +-06.0-[0e-12]-- | \-07.0-[13-17]-- # lspci -vvv -s 0033:01:00.0 | grep -i slot Physical Slot: WIO Slot3-1 ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ SlotPowerLimit 75.000W TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt- VC0: Caps: PATOffset=03 MaxTimeSlots=1 RejSnoopTrans- [root@ltc-boston11 ~]# [root@ltc-boston11 ~]# lspci -vvv -s 0033:01:00.0 | grep -i Upstream Capabilities: [68] Express (v2) Upstream Port, MSI 00 [root@ltc-boston11 ~]# [root@ltc-boston11 ~]# [root@ltc-boston11 ~]# lspci -vvv -s 0033:01:00.0 | grep -i hot Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) [root@ltc-boston11 ~]# [root@ltc-boston11 ~]# lspci -nn | grep 0033 0033:00:00.0 PCI bridge [0604]: IBM POWER9 Host Bridge (PHB4) [1014:04c1] 0033:01:00.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa) 0033:02:01.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa) 0033:02:04.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa) 0033:02:05.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa) 0033:02:06.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa) 0033:02:07.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa) 0033:0d:00.0 Non-Volatile memory controller [0108]: Samsung Electronics Co Ltd NVMe SSD Controller PM173X [144d:a824] [root@ltc-boston11 ~]# cat /sys/bus/pci/slots/WIO\ Slot3-1/address 0033:01:00 Hot-Unplug from above upstream port : # echo 0 > /sys/bus/pci/slots/WIO\ Slot3-1/power # lspci -tv +-[0033:00]---00.0-[01-17]-- Hot-plug from above upstream port : [root@ltc-boston11 ~]# echo 1 > /sys/bus/pci/slots/WIO\ Slot3-1/power [root@ltc-boston11 ~]# [root@ltc-boston11 ~]# [root@ltc-boston11 ~]# [root@ltc-boston11 ~]# lspci -tv +-[0033:00]---00.0-[01-17]----00.0-[02-17]--+-01.0-[03-07]-- | +-04.0-[08-0c]-- | +-05.0-[0d]----00.0 Samsung Electronics Co Ltd NVMe SSD Controller PM173X | +-06.0-[0e-12]-- | \-07.0-[13-17]-- What I want to say from above experiment is - if the upstream port is having the slot capability, pnv_php driver is able to do hot-plug/unplug operation on this. In our older case the upstream-port doesn't have slot capability, so there is no point of having hot-plug operation on this. Do you want to change the code logic to consider upstream-port always a slot? Is it even possible if lspci doesn't advertise it as a slot ? Best Regards, Krishna >>>> We wanted to handle the more generic case and did not want to be confined to >>>> only one device assumption. We want to fix the current inconsistent behavior >>>> more generically. >>> Right, as I said above I don't think handing the more generic case is >>> actually required if pnv_php is doing its job properly. It doesn't >>> hurt though. >>> >>>> Regarding the fix, the fix is obvious: >>> really? >>> >>>> We have to traverse >>>> and find the bridge ports from DT and invoke pci_scan_slot() on them. This will >>>> discover and create the entry for bridge ports (0004:02:00.0 to 0004:02:00.3 on >>>> the given bus- 0004:02). There is already an existing function, pci_scan_bridge() >>>> which is doing invocation of pci_scan_slot () for the devices behind the bridge, >>>> in this case for SAS device. So eventually, we are doing a scan of all the entities >>>> behind the slot. >>> I already read your patch so I'm not sure why you feel the need to >>> re-describe it in tedious detail. >>> >>>> Would you like me to combine the non-bridge and bridge cases into one? I can attempt >>>> to do this. Hopefully, if we incorporate the iterate sibling logic case correctly, >>>> we may not need to maintain these two separate cases for bridge and non-bridge. I >>>> will attempt this, and if it works, I will include it in the next patch. Thanks. >>> Yes, do that. > A single call of pci_scan_slot is sufficient to power on the devices in the scenario > with multiple ports on the same card. However, it is not enough for a switch > containing multiple ports. If the check is removed and we rely on the logic to > traverse all the sibling device nodes and invoke pci_scan_slot() on each, in > this case, device initialization of NIC ports (represented below) in terms of bar region > and so will occur multiple times. Although this is not a problem and it works fine, we > have to make a choice whether to proceed with or without the check. > > > Snippet showing multiple port from a single card. This is not on bridge but on same > card. > > +-[0001:00]---00.0-[01-0a]--+-00.0-[02-0a]--+-00.0-[03-07]-- > | | +-01.0-[08]--+-00.0 Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe > | | | +-00.1 Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe > | | | +-00.2 Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe > | | | \-00.3 Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe > | | +-02.0-[09]----00.0 Broadcom / LSI SAS3216 PCI-Express Fusion-MPT SAS-3 > | | \-03.0-[0a]----00.0 IBM PCI-E IPR SAS Adapter (ASIC) > | \-00.1 PMC-Sierra Inc. Device 4052 > > > Best regards, > Krishna > > >>> Also, do not post HTML emails to linux development lists. It breaks >>> plain text inline quoting which makes your messages annoying to reply >>> to. Some linux development lists will also silently drop HTML emails. >>> Please talk to the other LTC engineers about how to set up your mail >>> client to send plain text emails to avoid these problems in the >>> future. >>> >>> Oliver