Hi Geert, On Wed, 27 Apr 2022 16:58:07 +0200 Geert Uytterhoeven <geert@xxxxxxxxxxxxxx> wrote: > On Fri, Apr 22, 2022 at 2:09 PM Herve Codina <herve.codina@xxxxxxxxxxx> wrote: > > PM and PM_GENERIC_DOMAINS configs are required for RZ/N1 SOCs. > > Without these configs, the clocks used by the PCI bridge are not > > enabled and so accessing the devices leads to a kernel crash: > > [ 0.832958] Unhandled fault: external abort on non-linefetch (0x1008) at 0x90b5f848 > > > > Select PM and PM_GENERIC_DOMAINS for ARCH_RZN1 > > > > Signed-off-by: Herve Codina <herve.codina@xxxxxxxxxxx> > > Reviewed-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx> > i.e. will queue in renesas-devel for v5.19. > I plan to send a v4 of this series. As this patch (4/8) and the following one (5/8) will be queued for v5.19, I plan to remove them from the v4 version of the series. Is that ok for you or do you prefer to still have them in v4 ? Regards, Hervé -- Hervé Codina, Bootlin Embedded Linux and Kernel engineering https://bootlin.com