I have succeeded in keepin my rp3410 and rp3440 up to date but I have trouble on A500 after 4.8. Tried two kernels, something around 4.9-rc2 and 4.9.0-rc5-00297-g20afa6e, they both crash on boot like that. Hardware seems fine, I can boot kernels up to 4.8 without problems. After these messages it just sits there, no progress is made. PDT is empty. All fields see to be 0 for the alert, except timestamp ands alert level (=7). Is there anything in PIM that might be of interest? Bisecting slowly is possible. HARD Booted. palo ipl 1.95 portage@a500 Thu Jul 7 15:40:10 EEST 2016 Partition Start(MB) End(MB) Id Type 1 1 32 f0 Palo 2 33 224 83 ext2 3 225 31696 83 ext2 4 31697 34732 83 ext2 PALO(F0) partition contains: Command line for kernel: 'root=/dev/sda3 console=ttyS0 palo_kernel=2/vmlinux' Selected kernel: /vmlinux from partition 2 ************* SYSTEM ALERT ************** SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 7 = reserved REASON FOR ALERT SOURCE: 0 = unknown, no source stated SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: FF PROBLEM DETAIL: 0 = no problem detail LEDs: RUN ATTENTION FAULT REMOTE POWER FLASH FLASH OFF ON ON LED State: Running non-OS code. Non-critical error detected. Check Chassis and Console Logs for error messages. 0x0000007000FF6292 00000000 00000000 - type 0 = Data Field Unused 0x5800087000FF6292 0000740A 19151E19 - type 11 = Timestamp 11/25/2016 21:30:25 A: ack read of this entry - X: Disable all future alert messages Anything else skip redisplay the log entry ->Choice:Timeout! ***************************************** Interesting entries from SL GSP command from these seconds: Log Entry # 300 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 8 = I/O SOURCE DETAIL: 2 = system bus adapter SOURCE ID: 6 PROBLEM DETAIL: 3 = function failure CALLER ACTIVITY: 6 = machine check STATUS: 3 CALLER SUBACTIVITY: 34 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x7000002382066343 00000000 00070200 type 14 = Problem Detail 0x5800082382066343 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 301 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 8 = I/O SOURCE DETAIL: 2 = system bus adapter SOURCE ID: 4 PROBLEM DETAIL: 3 = function failure CALLER ACTIVITY: 6 = machine check STATUS: 3 CALLER SUBACTIVITY: 34 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x7000002382046343 00000000 00070200 type 14 = Problem Detail 0x5800082382046343 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 302 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 8 = I/O SOURCE DETAIL: 2 = system bus adapter SOURCE ID: 2 PROBLEM DETAIL: 3 = function failure CALLER ACTIVITY: 6 = machine check STATUS: 3 CALLER SUBACTIVITY: 34 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x7000002382026343 00000000 00070200 type 14 = Problem Detail 0x5800082382026343 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 303 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 8 = I/O SOURCE DETAIL: 2 = system bus adapter SOURCE ID: 0 PROBLEM DETAIL: 3 = function failure CALLER ACTIVITY: 6 = machine check STATUS: 3 CALLER SUBACTIVITY: 34 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x7000002382006343 00000000 00070200 type 14 = Problem Detail 0x5800082382006343 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 304 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 0 = No failure detected, forward progress SOURCE: 8 = I/O SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 0 CALLER SUBACTIVITY: 30 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x0000000080006300 00000000 00000001 type 0 = Data Field Unused 0x5800080080006300 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 305 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 0 = unknown, no source stated SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: FF PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 2 CALLER SUBACTIVITY: 40 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x0000002000FF6402 00000000 00000000 type 0 = Data Field Unused 0x5800082000FF6402 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 306 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 0 = unknown, no source stated SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: FF PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 2 CALLER SUBACTIVITY: 44 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x0000002000FF6442 00000000 00000000 type 0 = Data Field Unused 0x5800082000FF6442 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 307 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 0 = No failure detected, forward progress SOURCE: 8 = I/O SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: F CALLER SUBACTIVITY: 31 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x000000008000631F 00000000 00000000 type 0 = Data Field Unused 0x580008008000631F 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 308 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 0 = No failure detected, forward progress SOURCE: 8 = I/O SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 0 CALLER SUBACTIVITY: 31 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x0000000080006310 00000000 00000001 type 0 = Data Field Unused 0x5800080080006310 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 309 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 7 = memory SOURCE DETAIL: 9 = unexpected SOURCE ID: 0 PROBLEM DETAIL: 3 = unexpected CALLER ACTIVITY: 6 = machine check STATUS: 3 CALLER SUBACTIVITY: 13 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x7000002379006133 C1BFF0FF FED08040 type 14 = Problem Detail 0x5800082379006133 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 310 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 7 = memory SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 2 CALLER SUBACTIVITY: 08 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x7000002070006082 00000000 00392400 type 14 = Problem Detail 0x5800082070006082 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 311 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 7 = memory SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 2 CALLER SUBACTIVITY: 06 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x6000002070006062 00000000 00000010 type 12 = Device Status 0x5800082070006062 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 312 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 1 = Information only, no action required SOURCE: 6 = platform SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: FF PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 2 CALLER SUBACTIVITY: 2A = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0xA000001060FF62A2 00000000 0000050B type 20 = major change in system state 0x5800081060FF62A2 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 313 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 7 = reserved SOURCE: 0 = unknown, no source stated SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: FF PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 2 CALLER SUBACTIVITY: 29 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x0000007000FF6292 00000000 00000000 type 0 = Data Field Unused 0x5800087000FF6292 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 314 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 1 = processor SOURCE DETAIL: 1 = processor general SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 2 CALLER SUBACTIVITY: 31 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x1800002011006312 CB810000 00000000 type 3 = Actual Data 0x5800082011006312 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. Log Entry # 315 : SYSTEM NAME: a500-m DATE: 11/25/2016 TIME: 21:30:25 ALERT LEVEL: 2 = Non-Urgent operator attention required SOURCE: 0 = unknown, no source stated SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: FF PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 6 = machine check STATUS: 2 CALLER SUBACTIVITY: 24 = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x0000002000FF6242 00000000 00000000 type 0 = Data Field Unused 0x5800082000FF6242 0000740A 19151E19 type 11 = Timestamp 11/25/2016 21:30:25 Type CR for next entry, - CR for previous entry, Q CR to quit. -- Meelis Roos (mroos@xxxxxxxx) -- To unsubscribe from this list: send the line "unsubscribe linux-parisc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html