Hi Patrick, On Tue, Jul 05, 2011 at 02:35:12PM +0000, Gerber Patrick wrote: > I am using an over Fire with an omap3530. I have added a small Lithium > backup battery to the TWL4030 for RTC backup as recommanded by Gumstix. > I have tried to set the time with date command and shutdown the overo and > remove power. After restart the date is not the one that I have set but a > default one (always the same). > > Does anybody have already experienced this ? Do you have any idea ? Do 'hwclock -w' to set the RTC clock from the system clock. This should do the trick, assuming that you have the RTC driver compiled, or loaded as a module. baruch -- ~. .~ Tk Open Systems =}------------------------------------------------ooO--U--Ooo------------{= - baruch@xxxxxxxxxx - tel: +972.2.679.5364, http://www.tkos.co.il - -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html