It is preferred to use typed property access functions (i.e. of_property_read_<type> functions) rather than low-level of_get_property/of_find_property functions for reading properties. Convert reading boolean properties to to of_property_read_bool(). Signed-off-by: Rob Herring <robh@xxxxxxxxxx> --- arch/arm/mach-omap2/omap_hwmod.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/arch/arm/mach-omap2/omap_hwmod.c b/arch/arm/mach-omap2/omap_hwmod.c index 5a2a9b8e61ed..989195f6f7be 100644 --- a/arch/arm/mach-omap2/omap_hwmod.c +++ b/arch/arm/mach-omap2/omap_hwmod.c @@ -2322,11 +2322,11 @@ static int __init _init_mpu_rt_base(struct omap_hwmod *oh, void *data, static void __init parse_module_flags(struct omap_hwmod *oh, struct device_node *np) { - if (of_find_property(np, "ti,no-reset-on-init", NULL)) + if (of_property_read_bool(np, "ti,no-reset-on-init")) oh->flags |= HWMOD_INIT_NO_RESET; - if (of_find_property(np, "ti,no-idle-on-init", NULL)) + if (of_property_read_bool(np, "ti,no-idle-on-init")) oh->flags |= HWMOD_INIT_NO_IDLE; - if (of_find_property(np, "ti,no-idle", NULL)) + if (of_property_read_bool(np, "ti,no-idle")) oh->flags |= HWMOD_NO_IDLE; } -- 2.39.2