The error message if we cannot retrieve the clock tells us that the touchscreen controller clock was unavailable. This is wrong, this is the "main" clock for the hardware block, it is not specific to the touchscreen and won't change when we will introduce ADC1/magnetic reader support so let's correct this comment. Signed-off-by: Miquel Raynal <miquel.raynal@xxxxxxxxxxx> Reviewed-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> --- drivers/mfd/ti_am335x_tscadc.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/mfd/ti_am335x_tscadc.c b/drivers/mfd/ti_am335x_tscadc.c index 70a423e57067..9699fe6ca7eb 100644 --- a/drivers/mfd/ti_am335x_tscadc.c +++ b/drivers/mfd/ti_am335x_tscadc.c @@ -209,7 +209,7 @@ static int ti_tscadc_probe(struct platform_device *pdev) */ clk = devm_clk_get(&pdev->dev, NULL); if (IS_ERR(clk)) { - dev_err(&pdev->dev, "failed to get TSC fck\n"); + dev_err(&pdev->dev, "failed to get fck\n"); err = PTR_ERR(clk); goto err_disable_clk; } -- 2.27.0