[PATCH 0/5] cpcap battery simplification and calibrate support

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

This set of changes simplifies the coulomb counter code for cpcap-battery.
And the last patch in the series add support for coulomb counter calibration
on probe.

Regards,

Tony

Tony Lindgren (5):
  power: supply: cpcap-battery: Move coulomb counter units per lsb to
    ddata
  power: supply: cpcap-battery: Simplify coulomb counter calculation
    with div_s64
  power: supply: cpcap-battery: Simplify short term power average
    calculation
  power: supply: cpcap-battery: Read and save integrator register CCI
  power: supply: cpcap-battery: Add basic coulomb counter calibrate
    support

 drivers/power/supply/cpcap-battery.c | 178 +++++++++++++++++++--------
 1 file changed, 125 insertions(+), 53 deletions(-)

-- 