Re: [PATCH v1 05/11] dt-bindings: regulator: Change regulator-coupled-max-spread property

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 10/17/18 4:25 PM, Rob Herring wrote:
> On Fri, Oct 05, 2018 at 06:36:32PM +0300, Dmitry Osipenko wrote:
>> Redefine binding for regulator-coupled-max-spread property in a way that
>> max-spread values are defined per regulator couple instead of defining
>> single max-spread for the whole group of coupled regulators.
>>
>> With that change the following regulators coupling configuration will be
>> possible:
>>
>> regA: regulatorA {
>> 	regulator-coupled-with = <&regB &regC>;
>> 	regulator-coupled-max-spread = <100000 300000>;
>> };
>>
>> regB: regulatorB {
>> 	regulator-coupled-with = <&regA &regC>;
>> 	regulator-coupled-max-spread = <100000 200000>;
>> };
>>
>> regC: regulatorC {
>> 	regulator-coupled-with = <&regA &regB>;
>> 	regulator-coupled-max-spread = <300000 200000>;
>> };
>>
>> Signed-off-by: Dmitry Osipenko <digetx@xxxxxxxxx>
>> ---
>>  Documentation/devicetree/bindings/regulator/regulator.txt | 5 +++--
>>  1 file changed, 3 insertions(+), 2 deletions(-)
>>
>> diff --git a/Documentation/devicetree/bindings/regulator/regulator.txt b/Documentation/devicetree/bindings/regulator/regulator.txt
>> index a7cd36877bfe..9b525b657fca 100644
>> --- a/Documentation/devicetree/bindings/regulator/regulator.txt
>> +++ b/Documentation/devicetree/bindings/regulator/regulator.txt
>> @@ -76,8 +76,9 @@ Optional properties:
>>  - regulator-coupled-with: Regulators with which the regulator
>>    is coupled. The linkage is 2-way - all coupled regulators should be linked
>>    with each other. A regulator should not be coupled with its supplier.
>> -- regulator-coupled-max-spread: Max spread between voltages of coupled regulators
>> -  in microvolts.
>> +- regulator-coupled-max-spread: Array of maximum spread between voltages of
>> +  coupled regulators in microvolts, each value in the array relates to the
>> +  corresponding couple specified by the regulator-coupled-with property.
> 
> Is this in use already? How is a single entry handled?

No, it is not in use yet. Only some of the prerequisite patches were applied. 

Initially single entry was supposed to be re-used by all of regulator couples. Now single entry describes a single couple only.